1 | smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.9.0-0.bpo.5-amd64] (local build)
|
---|
2 | Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: WD3000FYYZ-23UL 81Y9799 81Y3865IBM
|
---|
6 | Firmware Version: WD40
|
---|
7 | User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
---|
8 | Sector Size: 512 bytes logical/physical
|
---|
9 | Rotation Rate: 7200 rpm
|
---|
10 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
11 | ATA Version is: ATA8-ACS (minor revision not indicated)
|
---|
12 | SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
---|
13 | Local Time is: Sat Jan 23 12:16:40 2021 CET
|
---|
14 | SMART support is: Available - device has SMART capability.
|
---|
15 | SMART support is: Enabled
|
---|
16 | AAM feature is: Unavailable
|
---|
17 | APM level is: 128 (minimum power consumption without standby)
|
---|
18 | Rd look-ahead is: Enabled
|
---|
19 | Write cache is: Enabled
|
---|
20 | DSN feature is: Unavailable
|
---|
21 | ATA Security is: Disabled, NOT FROZEN [SEC1]
|
---|
22 | Wt Cache Reorder: Enabled
|
---|
23 |
|
---|
24 | === START OF READ SMART DATA SECTION ===
|
---|
25 | SMART overall-health self-assessment test result: PASSED
|
---|
26 |
|
---|
27 | General SMART Values:
|
---|
28 | Offline data collection status: (0x02) Offline data collection activity
|
---|
29 | was completed without error.
|
---|
30 | Auto Offline Data Collection: Disabled.
|
---|
31 | Self-test execution status: ( 246) Self-test routine in progress...
|
---|
32 | 60% of test remaining.
|
---|
33 | Total time to complete Offline
|
---|
34 | data collection: (36000) seconds.
|
---|
35 | Offline data collection
|
---|
36 | capabilities: (0x7b) SMART execute Offline immediate.
|
---|
37 | Auto Offline data collection on/off support.
|
---|
38 | Suspend Offline collection upon new
|
---|
39 | command.
|
---|
40 | Offline surface scan supported.
|
---|
41 | Self-test supported.
|
---|
42 | Conveyance Self-test supported.
|
---|
43 | Selective Self-test supported.
|
---|
44 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
45 | power-saving mode.
|
---|
46 | Supports SMART auto save timer.
|
---|
47 | Error logging capability: (0x01) Error logging supported.
|
---|
48 | General Purpose Logging supported.
|
---|
49 | Short self-test routine
|
---|
50 | recommended polling time: ( 2) minutes.
|
---|
51 | Extended self-test routine
|
---|
52 | recommended polling time: ( 389) minutes.
|
---|
53 | Conveyance self-test routine
|
---|
54 | recommended polling time: ( 5) minutes.
|
---|
55 | SCT capabilities: (0x70bd) SCT Status supported.
|
---|
56 | SCT Error Recovery Control supported.
|
---|
57 | SCT Feature Control supported.
|
---|
58 | SCT Data Table supported.
|
---|
59 |
|
---|
60 | SMART Attributes Data Structure revision number: 16
|
---|
61 | Vendor Specific SMART Attributes with Thresholds:
|
---|
62 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
---|
63 | 1 Raw_Read_Error_Rate POSR-K 200 191 051 - 0
|
---|
64 | 3 Spin_Up_Time POS--K 227 227 021 - 7616
|
---|
65 | 4 Start_Stop_Count -O--CK 100 100 000 - 45
|
---|
66 | 5 Reallocated_Sector_Ct PO--CK 199 199 140 - 53
|
---|
67 | 7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
---|
68 | 9 Power_On_Hours -O--CK 072 072 000 - 20557
|
---|
69 | 10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
---|
70 | 11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
---|
71 | 12 Power_Cycle_Count -O--CK 100 100 000 - 45
|
---|
72 | 16 Unknown_Attribute -O---K 047 153 000 - 2573469547285
|
---|
73 | 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
---|
74 | 192 Power-Off_Retract_Count -O--CK 200 200 000 - 43
|
---|
75 | 193 Load_Cycle_Count -O--CK 200 200 000 - 1
|
---|
76 | 194 Temperature_Celsius -O---K 116 111 000 - 36
|
---|
77 | 195 Hardware_ECC_Recovered -OS-CK 200 200 000 - 0
|
---|
78 | 196 Reallocated_Event_Count -O--CK 199 199 000 - 1
|
---|
79 | 197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
---|
80 | 198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
---|
81 | 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
---|
82 | 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
---|
83 | ||||||_ K auto-keep
|
---|
84 | |||||__ C event count
|
---|
85 | ||||___ R error rate
|
---|
86 | |||____ S speed/performance
|
---|
87 | ||_____ O updated online
|
---|
88 | |______ P prefailure warning
|
---|
89 |
|
---|
90 | General Purpose Log Directory Version 1
|
---|
91 | SMART Log Directory Version 1 [multi-sector log support]
|
---|
92 | Address Access R/W Size Description
|
---|
93 | 0x00 GPL,SL R/O 1 Log Directory
|
---|
94 | 0x01 SL R/O 1 Summary SMART error log
|
---|
95 | 0x02 SL R/O 5 Comprehensive SMART error log
|
---|
96 | 0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
---|
97 | 0x04 GPL,SL R/O 8 Device Statistics log
|
---|
98 | 0x06 SL R/O 1 SMART self-test log
|
---|
99 | 0x07 GPL R/O 1 Extended self-test log
|
---|
100 | 0x08 GPL R/O 2 Power Conditions log
|
---|
101 | 0x09 SL R/W 1 Selective self-test log
|
---|
102 | 0x10 GPL R/O 1 NCQ Command Error log
|
---|
103 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
---|
104 | 0x24 GPL R/O 1 Current Device Internal Status Data log
|
---|
105 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
---|
106 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
---|
107 | 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
---|
108 | 0xa8-0xb1 GPL,SL VS 1 Device vendor specific log
|
---|
109 | 0xb2 GPL VS 65535 Device vendor specific log
|
---|
110 | 0xb2 SL VS 255 Device vendor specific log
|
---|
111 | 0xb3-0xb7 GPL,SL VS 1 Device vendor specific log
|
---|
112 | 0xbd GPL,SL VS 1 Device vendor specific log
|
---|
113 | 0xc0 GPL,SL VS 1 Device vendor specific log
|
---|
114 | 0xc1 GPL VS 24 Device vendor specific log
|
---|
115 | 0xd0 GPL VS 1 Device vendor specific log
|
---|
116 | 0xe0 GPL,SL R/W 1 SCT Command/Status
|
---|
117 | 0xe1 GPL,SL R/W 1 SCT Data Transfer
|
---|
118 |
|
---|
119 | SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
---|
120 | Device Error Count: 47 (device log contains only the most recent 24 errors)
|
---|
121 | CR = Command Register
|
---|
122 | FEATR = Features Register
|
---|
123 | COUNT = Count (was: Sector Count) Register
|
---|
124 | LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
---|
125 | LH = LBA High (was: Cylinder High) Register ] LBA
|
---|
126 | LM = LBA Mid (was: Cylinder Low) Register ] Register
|
---|
127 | LL = LBA Low (was: Sector Number) Register ]
|
---|
128 | DV = Device (was: Device/Head) Register
|
---|
129 | DC = Device Control Register
|
---|
130 | ER = Error register
|
---|
131 | ST = Status register
|
---|
132 | Powered_Up_Time is measured from power on, and printed as
|
---|
133 | DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
---|
134 | SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
---|
135 |
|
---|
136 | Error 47 [22] occurred at disk power-on lifetime: 20495 hours (853 days + 23 hours)
|
---|
137 | When the command that caused the error occurred, the device was active or idle.
|
---|
138 |
|
---|
139 | After command completion occurred, registers were:
|
---|
140 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
141 | -- -- -- == -- == == == -- -- -- -- --
|
---|
142 | 40 -- 51 00 00 00 01 17 3a ed 13 40 00 Error: UNC at LBA = 0x1173aed13 = 4684705043
|
---|
143 |
|
---|
144 | Commands leading to the command that caused the error were:
|
---|
145 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
146 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
147 | 60 01 00 00 00 00 01 17 3a ed 00 40 00 1d+16:37:35.435 READ FPDMA QUEUED
|
---|
148 | 60 01 00 00 00 00 01 17 3a ec 00 40 00 1d+16:37:35.434 READ FPDMA QUEUED
|
---|
149 | 60 01 00 00 00 00 01 17 3a eb 00 40 00 1d+16:37:35.433 READ FPDMA QUEUED
|
---|
150 | 60 01 00 00 00 00 01 17 3a ea 00 40 00 1d+16:37:35.432 READ FPDMA QUEUED
|
---|
151 | 60 01 00 00 00 00 01 17 3a e9 00 40 00 1d+16:37:35.430 READ FPDMA QUEUED
|
---|
152 |
|
---|
153 | Error 46 [21] occurred at disk power-on lifetime: 18318 hours (763 days + 6 hours)
|
---|
154 | When the command that caused the error occurred, the device was active or idle.
|
---|
155 |
|
---|
156 | After command completion occurred, registers were:
|
---|
157 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
158 | -- -- -- == -- == == == -- -- -- -- --
|
---|
159 | 40 -- 51 10 00 00 01 17 3a bc 97 40 00 Error: UNC at LBA = 0x1173abc97 = 4684692631
|
---|
160 |
|
---|
161 | Commands leading to the command that caused the error were:
|
---|
162 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
163 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
164 | 42 00 00 10 00 00 01 17 3a b0 00 40 00 23d+06:42:45.164 READ VERIFY SECTOR(S) EXT
|
---|
165 | 42 00 00 10 00 00 01 17 3a a0 00 40 00 23d+06:42:45.070 READ VERIFY SECTOR(S) EXT
|
---|
166 | 42 00 00 10 00 00 01 17 3a 90 00 40 00 23d+06:42:45.051 READ VERIFY SECTOR(S) EXT
|
---|
167 | 42 00 00 10 00 00 01 17 3a 80 00 40 00 23d+06:42:45.036 READ VERIFY SECTOR(S) EXT
|
---|
168 | 42 00 00 10 00 00 01 17 3a 70 00 40 00 23d+06:42:45.020 READ VERIFY SECTOR(S) EXT
|
---|
169 |
|
---|
170 | Error 45 [20] occurred at disk power-on lifetime: 17815 hours (742 days + 7 hours)
|
---|
171 | When the command that caused the error occurred, the device was active or idle.
|
---|
172 |
|
---|
173 | After command completion occurred, registers were:
|
---|
174 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
175 | -- -- -- == -- == == == -- -- -- -- --
|
---|
176 | 40 -- 51 10 00 00 01 17 3a b5 b8 40 00 Error: UNC at LBA = 0x1173ab5b8 = 4684690872
|
---|
177 |
|
---|
178 | Commands leading to the command that caused the error were:
|
---|
179 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
180 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
181 | 42 00 00 10 00 00 01 17 3a b0 00 40 00 2d+07:40:23.347 READ VERIFY SECTOR(S) EXT
|
---|
182 | 42 00 00 10 00 00 01 17 3a a0 00 40 00 2d+07:40:23.253 READ VERIFY SECTOR(S) EXT
|
---|
183 | 42 00 00 10 00 00 01 17 3a 90 00 40 00 2d+07:40:23.234 READ VERIFY SECTOR(S) EXT
|
---|
184 | 42 00 00 10 00 00 01 17 3a 80 00 40 00 2d+07:40:23.218 READ VERIFY SECTOR(S) EXT
|
---|
185 | 42 00 00 10 00 00 01 17 3a 70 00 40 00 2d+07:40:23.202 READ VERIFY SECTOR(S) EXT
|
---|
186 |
|
---|
187 | Error 44 [19] occurred at disk power-on lifetime: 17809 hours (742 days + 1 hours)
|
---|
188 | When the command that caused the error occurred, the device was active or idle.
|
---|
189 |
|
---|
190 | After command completion occurred, registers were:
|
---|
191 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
192 | -- -- -- == -- == == == -- -- -- -- --
|
---|
193 | 40 -- 51 00 00 00 01 17 1d 43 a7 40 00 Error: UNC at LBA = 0x1171d43a7 = 4682761127
|
---|
194 |
|
---|
195 | Commands leading to the command that caused the error were:
|
---|
196 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
197 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
198 | 60 01 00 00 00 00 01 17 1d 43 00 40 00 2d+01:08:38.669 READ FPDMA QUEUED
|
---|
199 | 60 01 00 00 00 00 01 17 1d 42 00 40 00 2d+01:08:38.668 READ FPDMA QUEUED
|
---|
200 | 60 01 00 00 00 00 01 17 1d 41 00 40 00 2d+01:08:38.667 READ FPDMA QUEUED
|
---|
201 | 60 01 00 00 00 00 01 17 1d 40 00 40 00 2d+01:08:38.666 READ FPDMA QUEUED
|
---|
202 | 60 01 00 00 00 00 01 17 1d 3f 00 40 00 2d+01:08:38.664 READ FPDMA QUEUED
|
---|
203 |
|
---|
204 | Error 43 [18] occurred at disk power-on lifetime: 17662 hours (735 days + 22 hours)
|
---|
205 | When the command that caused the error occurred, the device was active or idle.
|
---|
206 |
|
---|
207 | After command completion occurred, registers were:
|
---|
208 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
209 | -- -- -- == -- == == == -- -- -- -- --
|
---|
210 | 40 -- 51 00 00 00 01 17 3a b5 b8 40 00 Error: UNC at LBA = 0x1173ab5b8 = 4684690872
|
---|
211 |
|
---|
212 | Commands leading to the command that caused the error were:
|
---|
213 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
214 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
215 | 60 01 00 00 08 00 01 17 3a b6 00 40 00 45d+14:59:02.371 READ FPDMA QUEUED
|
---|
216 | 60 01 00 00 00 00 01 17 3a b5 00 40 00 45d+14:59:02.368 READ FPDMA QUEUED
|
---|
217 | 60 01 00 00 00 00 01 17 3a b3 00 40 00 45d+14:59:02.362 READ FPDMA QUEUED
|
---|
218 | 60 01 00 00 00 00 01 17 3a b2 00 40 00 45d+14:59:02.359 READ FPDMA QUEUED
|
---|
219 | 60 01 00 00 08 00 01 17 3a b1 00 40 00 45d+14:59:02.357 READ FPDMA QUEUED
|
---|
220 |
|
---|
221 | Error 42 [17] occurred at disk power-on lifetime: 17641 hours (735 days + 1 hours)
|
---|
222 | When the command that caused the error occurred, the device was active or idle.
|
---|
223 |
|
---|
224 | After command completion occurred, registers were:
|
---|
225 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
226 | -- -- -- == -- == == == -- -- -- -- --
|
---|
227 | 40 -- 51 00 00 00 01 17 1d 28 2a 40 00 Error: UNC at LBA = 0x1171d282a = 4682754090
|
---|
228 |
|
---|
229 | Commands leading to the command that caused the error were:
|
---|
230 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
231 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
232 | 60 01 00 00 00 00 01 17 1d 28 00 40 00 44d+18:16:44.446 READ FPDMA QUEUED
|
---|
233 | 60 01 00 00 00 00 01 17 1d 27 00 40 00 44d+18:16:44.445 READ FPDMA QUEUED
|
---|
234 | 60 01 00 00 00 00 01 17 1d 26 00 40 00 44d+18:16:44.443 READ FPDMA QUEUED
|
---|
235 | 60 01 00 00 00 00 01 17 1d 25 00 40 00 44d+18:16:44.442 READ FPDMA QUEUED
|
---|
236 | 60 01 00 00 00 00 01 17 1d 24 00 40 00 44d+18:16:44.441 READ FPDMA QUEUED
|
---|
237 |
|
---|
238 | Error 41 [16] occurred at disk power-on lifetime: 16641 hours (693 days + 9 hours)
|
---|
239 | When the command that caused the error occurred, the device was active or idle.
|
---|
240 |
|
---|
241 | After command completion occurred, registers were:
|
---|
242 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
243 | -- -- -- == -- == == == -- -- -- -- --
|
---|
244 | 40 -- 51 00 00 00 01 17 1d 05 6c 40 00 Error: UNC at LBA = 0x1171d056c = 4682745196
|
---|
245 |
|
---|
246 | Commands leading to the command that caused the error were:
|
---|
247 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
248 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
249 | 60 00 98 00 08 00 01 17 1d 05 68 40 00 3d+01:50:29.423 READ FPDMA QUEUED
|
---|
250 | 60 00 68 00 00 00 01 17 1d 05 00 40 00 3d+01:50:29.423 READ FPDMA QUEUED
|
---|
251 | 42 00 00 10 00 00 00 21 d6 d0 00 40 00 3d+01:50:29.394 READ VERIFY SECTOR(S) EXT
|
---|
252 | 60 01 00 00 00 00 01 17 1d 08 00 40 00 3d+01:50:29.392 READ FPDMA QUEUED
|
---|
253 | 60 00 6c 00 10 00 01 17 1d 05 00 40 00 3d+01:50:29.369 READ FPDMA QUEUED
|
---|
254 |
|
---|
255 | Error 40 [15] occurred at disk power-on lifetime: 16641 hours (693 days + 9 hours)
|
---|
256 | When the command that caused the error occurred, the device was active or idle.
|
---|
257 |
|
---|
258 | After command completion occurred, registers were:
|
---|
259 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
---|
260 | -- -- -- == -- == == == -- -- -- -- --
|
---|
261 | 40 -- 51 00 00 00 01 17 1d 05 6c 40 00 Error: UNC at LBA = 0x1171d056c = 4682745196
|
---|
262 |
|
---|
263 | Commands leading to the command that caused the error were:
|
---|
264 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
---|
265 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
---|
266 | 60 01 00 00 00 00 01 17 1d 05 00 40 00 3d+01:50:27.549 READ FPDMA QUEUED
|
---|
267 | 60 01 00 00 00 00 01 17 1d 04 00 40 00 3d+01:50:27.545 READ FPDMA QUEUED
|
---|
268 | 60 01 00 00 00 00 01 17 1d 03 00 40 00 3d+01:50:27.542 READ FPDMA QUEUED
|
---|
269 | 60 01 00 00 00 00 01 17 1d 01 00 40 00 3d+01:50:27.536 READ FPDMA QUEUED
|
---|
270 | 60 01 00 00 08 00 01 17 1d 00 00 40 00 3d+01:50:27.535 READ FPDMA QUEUED
|
---|
271 |
|
---|
272 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
---|
273 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
---|
274 | # 1 Short offline Self-test routine in progress 60% 20557 -
|
---|
275 | # 2 Extended offline Completed without error 00% 20548 -
|
---|
276 |
|
---|
277 | SMART Selective self-test log data structure revision number 1
|
---|
278 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
279 | 1 0 0 Not_testing
|
---|
280 | 2 0 0 Not_testing
|
---|
281 | 3 0 0 Not_testing
|
---|
282 | 4 0 0 Not_testing
|
---|
283 | 5 0 0 Not_testing
|
---|
284 | Selective self-test flags (0x0):
|
---|
285 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
286 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
287 |
|
---|
288 | SCT Status Version: 3
|
---|
289 | SCT Version (vendor specific): 258 (0x0102)
|
---|
290 | Device State: DST executing in background (3)
|
---|
291 | Current Temperature: 36 Celsius
|
---|
292 | Power Cycle Min/Max Temperature: 31/40 Celsius
|
---|
293 | Lifetime Min/Max Temperature: 21/41 Celsius
|
---|
294 | Specified Max Operating Temperature: 60 Celsius
|
---|
295 | Under/Over Temperature Limit Count: 0/0
|
---|
296 | Vendor specific:
|
---|
297 | 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
---|
298 | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
---|
299 |
|
---|
300 | SCT Temperature History Version: 2
|
---|
301 | Temperature Sampling Period: 1 minute
|
---|
302 | Temperature Logging Interval: 1 minute
|
---|
303 | Min/Max recommended Temperature: 0/60 Celsius
|
---|
304 | Min/Max Temperature Limit: -41/85 Celsius
|
---|
305 | Temperature History Size (Index): 478 (244)
|
---|
306 |
|
---|
307 | Index Estimated Time Temperature Celsius
|
---|
308 | 245 2021-01-23 04:19 36 *****************
|
---|
309 | ... ..(476 skipped). .. *****************
|
---|
310 | 244 2021-01-23 12:16 36 *****************
|
---|
311 |
|
---|
312 | SCT Error Recovery Control:
|
---|
313 | Read: 70 (7.0 seconds)
|
---|
314 | Write: 70 (7.0 seconds)
|
---|
315 |
|
---|
316 | Device Statistics (GP Log 0x04)
|
---|
317 | Page Offset Size Value Flags Description
|
---|
318 | 0x01 ===== = = === == General Statistics (rev 2) ==
|
---|
319 | 0x01 0x008 4 45 --- Lifetime Power-On Resets
|
---|
320 | 0x01 0x010 4 20557 --- Power-on Hours
|
---|
321 | 0x01 0x018 6 1556262443474 --- Logical Sectors Written
|
---|
322 | 0x01 0x020 6 942684715 --- Number of Write Commands
|
---|
323 | 0x01 0x028 6 1017207103832 --- Logical Sectors Read
|
---|
324 | 0x01 0x030 6 4152049099 --- Number of Read Commands
|
---|
325 | 0x01 0x048 2 4791 N-- Workload Utilization
|
---|
326 | 0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
---|
327 | 0x03 0x008 4 20377 --- Spindle Motor Power-on Hours
|
---|
328 | 0x03 0x010 4 20377 --- Head Flying Hours
|
---|
329 | 0x03 0x018 4 45 --- Head Load Events
|
---|
330 | 0x03 0x020 4 199 N-- Number of Reallocated Logical Sectors
|
---|
331 | 0x03 0x028 4 528 --- Read Recovery Attempts
|
---|
332 | 0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
---|
333 | 0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
---|
334 | 0x04 0x008 4 47 --- Number of Reported Uncorrectable Errors
|
---|
335 | 0x04 0x010 4 39 --- Resets Between Cmd Acceptance and Completion
|
---|
336 | 0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
---|
337 | 0x05 0x008 1 36 --- Current Temperature
|
---|
338 | 0x05 0x010 1 36 --- Average Short Term Temperature
|
---|
339 | 0x05 0x018 1 32 --- Average Long Term Temperature
|
---|
340 | 0x05 0x020 1 39 --- Highest Temperature
|
---|
341 | 0x05 0x028 1 27 --- Lowest Temperature
|
---|
342 | 0x05 0x030 1 36 --- Highest Average Short Term Temperature
|
---|
343 | 0x05 0x038 1 31 --- Lowest Average Short Term Temperature
|
---|
344 | 0x05 0x040 1 35 --- Highest Average Long Term Temperature
|
---|
345 | 0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
---|
346 | 0x05 0x050 4 0 --- Time in Over-Temperature
|
---|
347 | 0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
---|
348 | 0x05 0x060 4 0 --- Time in Under-Temperature
|
---|
349 | 0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
---|
350 | 0x06 ===== = = === == Transport Statistics (rev 1) ==
|
---|
351 | 0x06 0x008 4 109 --- Number of Hardware Resets
|
---|
352 | 0x06 0x010 4 42 --- Number of ASR Events
|
---|
353 | 0x06 0x018 4 0 --- Number of Interface CRC Errors
|
---|
354 | |||_ C monitored condition met
|
---|
355 | ||__ D supports DSN
|
---|
356 | |___ N normalized value
|
---|
357 |
|
---|
358 | Pending Defects log (GP Log 0x0c) not supported
|
---|
359 |
|
---|
360 | SATA Phy Event Counters (GP Log 0x11)
|
---|
361 | ID Size Value Description
|
---|
362 | 0x0001 2 0 Command failed due to ICRC error
|
---|
363 | 0x0002 2 0 R_ERR response for data FIS
|
---|
364 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
---|
365 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
---|
366 | 0x0005 2 0 R_ERR response for non-data FIS
|
---|
367 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
---|
368 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
---|
369 | 0x0008 2 0 Device-to-host non-data FIS retries
|
---|
370 | 0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
---|
371 | 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
---|
372 | 0x000b 2 0 CRC errors within host-to-device FIS
|
---|
373 | 0x000d 2 0 Non-CRC errors within host-to-device FIS
|
---|
374 | 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
---|
375 | 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
---|
376 | 0x8000 4 90199 Vendor specific
|
---|
377 |
|
---|