Ticket #1401: smartctl-Intel-INTELSSDSA2SH064G1IB.txt

File smartctl-Intel-INTELSSDSA2SH064G1IB.txt, 5.3 KB (added by Andrei Ivanov, 4 years ago)
Line 
1smartctl 7.1 2020-11-01 r5110 [x86_64-linux-3.10.0-1160.6.1.el7.x86_64] (local build)
2Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Model Family: Intel X25-E SSDs
6Device Model: INTELSSDSA2SH064G1IB 43W7659 44E9163IBM
7Serial Number: CVEM92130090064KGN
8LU WWN Device Id: 5 001517 958d8068a
9Firmware Version: 447C8860
10User Capacity: 64,023,257,088 bytes [64.0 GB]
11Sector Size: 512 bytes logical/physical
12Rotation Rate: Solid State Device
13Device is: In smartctl database [for details use: -P show]
14ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
15SATA Version is: SATA 2.6, 3.0 Gb/s
16Local Time is: Thu Nov 26 18:46:59 2020 PST
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is: Unavailable
20APM feature is: Unavailable
21Rd look-ahead is: Enabled
22Write cache is: Enabled
23DSN feature is: Unavailable
24ATA Security is: Disabled, frozen [SEC2]
25Wt Cache Reorder: Unavailable
26
27=== START OF READ SMART DATA SECTION ===
28SMART overall-health self-assessment test result: PASSED
29
30General SMART Values:
31Offline data collection status: (0x00) Offline data collection activity
32 was never started.
33 Auto Offline Data Collection: Disabled.
34Self-test execution status: ( 32) The self-test routine was interrupted
35 by the host with a hard or soft reset.
36Total time to complete Offline
37data collection: ( 1) seconds.
38Offline data collection
39capabilities: (0x75) SMART execute Offline immediate.
40 No Auto Offline data collection support.
41 Abort Offline collection upon new
42 command.
43 No Offline surface scan supported.
44 Self-test supported.
45 Conveyance Self-test supported.
46 Selective Self-test supported.
47SMART capabilities: (0x0003) Saves SMART data before entering
48 power-saving mode.
49 Supports SMART auto save timer.
50Error logging capability: (0x01) Error logging supported.
51 General Purpose Logging supported.
52Short self-test routine
53recommended polling time: ( 2) minutes.
54Extended self-test routine
55recommended polling time: ( 4) minutes.
56Conveyance self-test routine
57recommended polling time: ( 1) minutes.
58
59SMART Attributes Data Structure revision number: 5
60Vendor Specific SMART Attributes with Thresholds:
61ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
62 3 Spin_Up_Time ------ 100 000 000 - 0
63 4 Start_Stop_Count ------ 100 000 000 - 0
64 5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
65 9 Power_On_Hours -O---- 100 100 000 - 14015
66 12 Power_Cycle_Count -O---- 100 100 000 - 845
67192 Unsafe_Shutdown_Count -O---- 100 100 000 - 618
68232 Available_Reservd_Space PO---- 100 100 010 - 0
69233 Media_Wearout_Indicator -O---- 099 099 000 - 0
70225 Host_Writes_32MiB ------ 200 200 000 - 759007
71226 Intel_Internal -O---- 255 000 000 - 0
72227 Intel_Internal -O---- 000 000 000 - 0
73228 Intel_Internal -O---- 000 000 000 - 0
74 ||||||_ K auto-keep
75 |||||__ C event count
76 ||||___ R error rate
77 |||____ S speed/performance
78 ||_____ O updated online
79 |______ P prefailure warning
80
81General Purpose Log Directory Version 0
82SMART Log Directory Version 1 [multi-sector log support]
83Address Access R/W Size Description
840x00 GPL,SL R/O 1 Log Directory
850x01 SL R/O 1 Summary SMART error log
860x02 SL R/O 8 Comprehensive SMART error log
870x03 SL R/O 1 Ext. Comprehensive SMART error log
880x06 SL R/O 1 SMART self-test log
890x07 SL R/O 1 Extended self-test log
900x10 GPL R/O 1 NCQ Command Error log
910x4d GPL - 1 Reserved
920x80-0x9f SL R/W 16 Host vendor specific log
930xff GPL - 65024 Reserved
94
95SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
96
97SMART Error Log Version: 1
98No Errors Logged
99
100SMART Extended Self-test Log (GP Log 0x07) not supported
101
102SMART Self-test log structure revision number 1
103Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
104# 1 Extended offline Completed without error 00% 10454 -
105# 2 Extended offline Completed without error 00% 6227 -
106# 3 Short offline Completed without error 00% 1661 -
107
108SMART Selective self-test log data structure revision number 0
109Note: revision number not 1 implies that no selective self-test has ever been run
110 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
111 1 0 0 Not_testing
112 2 0 0 Not_testing
113 3 0 0 Not_testing
114 4 0 0 Not_testing
115 5 0 0 Not_testing
116Selective self-test flags (0x0):
117 After scanning selected spans, do NOT read-scan remainder of disk.
118If Selective self-test is pending on power-up, resume after 0 minute delay.
119
120SCT Commands not supported
121
122Device Statistics (GP/SMART Log 0x04) not supported
123
124Pending Defects log (GP Log 0x0c) not supported