1 | smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.3.18-lp152.41-default] (SUSE RPM)
|
---|
2 | Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: Seagate BarraCuda 120 SSD ZA1000CM10003
|
---|
6 | Serial Number: 7QW01EF7
|
---|
7 | LU WWN Device Id: 5 000c50 0bb1e14ee
|
---|
8 | Firmware Version: STRSD013
|
---|
9 | User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
---|
10 | Sector Size: 512 bytes logical/physical
|
---|
11 | Rotation Rate: Solid State Device
|
---|
12 | Form Factor: 2.5 inches
|
---|
13 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
14 | ATA Version is: ACS-3 (minor revision not indicated)
|
---|
15 | SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
---|
16 | Local Time is: Mon Sep 21 07:48:03 2020 CEST
|
---|
17 | SMART support is: Available - device has SMART capability.
|
---|
18 | SMART support is: Enabled
|
---|
19 | AAM feature is: Unavailable
|
---|
20 | APM level is: 254 (maximum performance)
|
---|
21 | Rd look-ahead is: Enabled
|
---|
22 | Write cache is: Enabled
|
---|
23 | DSN feature is: Unavailable
|
---|
24 | ATA Security is: Disabled, frozen [SEC2]
|
---|
25 | Wt Cache Reorder: Unavailable
|
---|
26 |
|
---|
27 | === START OF READ SMART DATA SECTION ===
|
---|
28 | SMART overall-health self-assessment test result: PASSED
|
---|
29 |
|
---|
30 | General SMART Values:
|
---|
31 | Offline data collection status: (0x00) Offline data collection activity
|
---|
32 | was never started.
|
---|
33 | Auto Offline Data Collection: Disabled.
|
---|
34 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
35 | without error or no self-test has ever
|
---|
36 | been run.
|
---|
37 | Total time to complete Offline
|
---|
38 | data collection: ( 30) seconds.
|
---|
39 | Offline data collection
|
---|
40 | capabilities: (0x79) SMART execute Offline immediate.
|
---|
41 | No Auto Offline data collection support.
|
---|
42 | Suspend Offline collection upon new
|
---|
43 | command.
|
---|
44 | Offline surface scan supported.
|
---|
45 | Self-test supported.
|
---|
46 | Conveyance Self-test supported.
|
---|
47 | Selective Self-test supported.
|
---|
48 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
49 | power-saving mode.
|
---|
50 | Supports SMART auto save timer.
|
---|
51 | Error logging capability: (0x01) Error logging supported.
|
---|
52 | General Purpose Logging supported.
|
---|
53 | Short self-test routine
|
---|
54 | recommended polling time: ( 1) minutes.
|
---|
55 | Extended self-test routine
|
---|
56 | recommended polling time: ( 2) minutes.
|
---|
57 | Conveyance self-test routine
|
---|
58 | recommended polling time: ( 3) minutes.
|
---|
59 |
|
---|
60 | SMART Attributes Data Structure revision number: 16
|
---|
61 | Vendor Specific SMART Attributes with Thresholds:
|
---|
62 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
---|
63 | 1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
---|
64 | 9 Power_On_Hours -O--C- 100 100 000 - 67
|
---|
65 | 12 Power_Cycle_Count -O--C- 100 100 000 - 77
|
---|
66 | 16 Unknown_Attribute -O--C- 100 100 000 - 2286
|
---|
67 | 17 Unknown_Attribute -O--C- 100 100 000 - 2286
|
---|
68 | 168 Unknown_Attribute -O--C- 100 100 000 - 0
|
---|
69 | 170 Unknown_Attribute PO---- 100 100 010 - 453
|
---|
70 | 173 Unknown_Attribute -O--C- 100 100 000 - 4295163909
|
---|
71 | 174 Unknown_Attribute -O--C- 100 100 000 - 66
|
---|
72 | 177 Wear_Leveling_Count ------ 100 100 000 - 0
|
---|
73 | 192 Power-Off_Retract_Count -O--C- 100 100 000 - 66
|
---|
74 | 194 Temperature_Celsius PO---K 102 091 000 - 25 (Min/Max 20/36)
|
---|
75 | 218 Unknown_Attribute PO-R-- 100 100 050 - 0
|
---|
76 | 231 Unknown_SSD_Attribute PO--C- 100 100 000 - 99
|
---|
77 | 232 Available_Reservd_Space PO--C- 100 100 000 - 0
|
---|
78 | 233 Media_Wearout_Indicator PO-R-- 100 100 000 - 1739
|
---|
79 | 235 Unknown_Attribute PO-R-- 100 100 000 - 3647424640
|
---|
80 | 241 Total_LBAs_Written -O--C- 100 100 000 - 1234
|
---|
81 | 242 Total_LBAs_Read -O--C- 100 100 000 - 280
|
---|
82 | ||||||_ K auto-keep
|
---|
83 | |||||__ C event count
|
---|
84 | ||||___ R error rate
|
---|
85 | |||____ S speed/performance
|
---|
86 | ||_____ O updated online
|
---|
87 | |______ P prefailure warning
|
---|
88 |
|
---|
89 | General Purpose Log Directory Version 1
|
---|
90 | SMART Log Directory Version 1 [multi-sector log support]
|
---|
91 | Address Access R/W Size Description
|
---|
92 | 0x00 GPL,SL R/O 1 Log Directory
|
---|
93 | 0x01 SL R/O 1 Summary SMART error log
|
---|
94 | 0x02 SL R/O 51 Comprehensive SMART error log
|
---|
95 | 0x03 GPL R/O 64 Ext. Comprehensive SMART error log
|
---|
96 | 0x04 GPL,SL R/O 8 Device Statistics log
|
---|
97 | 0x06 SL R/O 1 SMART self-test log
|
---|
98 | 0x07 GPL R/O 1 Extended self-test log
|
---|
99 | 0x09 SL R/W 1 Selective self-test log
|
---|
100 | 0x10 GPL R/O 1 NCQ Command Error log
|
---|
101 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
---|
102 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
---|
103 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
---|
104 | 0xc1 GPL VS 32760 Device vendor specific log
|
---|
105 | 0xc2 GPL VS 8 Device vendor specific log
|
---|
106 | 0xc3-0xcb GPL VS 32760 Device vendor specific log
|
---|
107 | 0xdc GPL VS 16 Device vendor specific log
|
---|
108 | 0xdf GPL VS 32760 Device vendor specific log
|
---|
109 |
|
---|
110 | SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
---|
111 | No Errors Logged
|
---|
112 |
|
---|
113 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
---|
114 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
---|
115 | # 1 Short offline Completed without error 00% 0 -
|
---|
116 | # 2 Short offline Completed without error 00% 0 -
|
---|
117 | # 3 Short offline Completed without error 00% 0 -
|
---|
118 | # 4 Short offline Completed without error 00% 0 -
|
---|
119 | # 5 Extended offline Completed without error 00% 0 -
|
---|
120 |
|
---|
121 | SMART Selective self-test log data structure revision number 1
|
---|
122 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
123 | 1 0 0 Not_testing
|
---|
124 | 2 0 0 Not_testing
|
---|
125 | 3 0 0 Not_testing
|
---|
126 | 4 0 0 Not_testing
|
---|
127 | 5 0 0 Not_testing
|
---|
128 | Selective self-test flags (0x0):
|
---|
129 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
130 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
131 |
|
---|
132 | SCT Commands not supported
|
---|
133 |
|
---|
134 | Device Statistics (GP Log 0x04)
|
---|
135 | Page Offset Size Value Flags Description
|
---|
136 | 0x01 ===== = = === == General Statistics (rev 1) ==
|
---|
137 | 0x01 0x008 4 77 --- Lifetime Power-On Resets
|
---|
138 | 0x01 0x010 4 67 --- Power-on Hours
|
---|
139 | 0x01 0x018 6 2589147700 --- Logical Sectors Written
|
---|
140 | 0x01 0x020 6 8609646935 --- Number of Write Commands
|
---|
141 | 0x01 0x028 6 589025644 --- Logical Sectors Read
|
---|
142 | 0x01 0x030 6 8598133544 --- Number of Read Commands
|
---|
143 | 0x01 0x038 6 242009616 --- Date and Time TimeStamp
|
---|
144 | 0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
---|
145 | 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
---|
146 | 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
---|
147 | 0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
---|
148 | 0x05 0x008 1 25 --- Current Temperature
|
---|
149 | 0x05 0x010 1 - --- Average Short Term Temperature
|
---|
150 | 0x05 0x018 1 - --- Average Long Term Temperature
|
---|
151 | 0x05 0x020 1 36 --- Highest Temperature
|
---|
152 | 0x05 0x028 1 20 --- Lowest Temperature
|
---|
153 | 0x05 0x030 1 - --- Highest Average Short Term Temperature
|
---|
154 | 0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
---|
155 | 0x05 0x040 1 - --- Highest Average Long Term Temperature
|
---|
156 | 0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
---|
157 | 0x05 0x050 4 0 --- Time in Over-Temperature
|
---|
158 | 0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
---|
159 | 0x05 0x060 4 0 --- Time in Under-Temperature
|
---|
160 | 0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
---|
161 | 0x06 ===== = = === == Transport Statistics (rev 1) ==
|
---|
162 | 0x06 0x008 4 225 --- Number of Hardware Resets
|
---|
163 | 0x06 0x018 4 0 --- Number of Interface CRC Errors
|
---|
164 | 0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
---|
165 | 0x07 0x008 1 1 --- Percentage Used Endurance Indicator
|
---|
166 | |||_ C monitored condition met
|
---|
167 | ||__ D supports DSN
|
---|
168 | |___ N normalized value
|
---|
169 |
|
---|
170 | Pending Defects log (GP Log 0x0c) not supported
|
---|
171 |
|
---|
172 | SATA Phy Event Counters (GP Log 0x11)
|
---|
173 | ID Size Value Description
|
---|
174 | 0x0001 2 0 Command failed due to ICRC error
|
---|
175 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
---|
176 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
---|
177 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
---|
178 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
---|
179 | 0x0008 2 0 Device-to-host non-data FIS retries
|
---|
180 | 0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
|
---|
181 | 0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
---|
182 | 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
---|
183 | 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
---|
184 | 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
---|
185 | 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
---|
186 |
|
---|