Ticket #1354: TEAM-L3-EVO-120GB.txt

File TEAM-L3-EVO-120GB.txt, 4.9 KB (added by Tony den Haan, 4 years ago)

Team L# EVO 120GB

Line 
1smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-37-generic] (local build)
2Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: TEAM L3 EVO SSD 120GB
6Serial Number: 3E6D0773184400018089
7LU WWN Device Id: 5 000000 000000000
8Firmware Version: SBFM11.0
9User Capacity: 120,034,123,776 bytes [120 GB]
10Sector Size: 512 bytes logical/physical
11Rotation Rate: Solid State Device
12Form Factor: 2.5 inches
13Device is: Not in smartctl database [for details use: -P showall]
14ATA Version is: ACS-4 (minor revision not indicated)
15SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
16Local Time is: Mon Jul 27 13:31:01 2020 CEST
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is: Unavailable
20APM feature is: Unavailable
21Rd look-ahead is: Enabled
22Write cache is: Enabled
23DSN feature is: Unavailable
24ATA Security is: Disabled, NOT FROZEN [SEC1]
25Wt Cache Reorder: Unavailable
26
27=== START OF READ SMART DATA SECTION ===
28SMART Status command failed
29Please get assistance from https://www.smartmontools.org/
30Register values returned from SMART Status command are:
31 ERR=0x53, SC=0x42, LL=0x6c, LM=0x00, LH=0x00, DEV=0x00, STS=0x55
32SMART Status not supported: Invalid ATA output register values
33SMART overall-health self-assessment test result: PASSED
34Warning: This result is based on an Attribute check.
35See vendor-specific Attribute list for marginal Attributes.
36
37General SMART Values:
38Offline data collection status: (0x00) Offline data collection activity
39 was never started.
40 Auto Offline Data Collection: Disabled.
41Total time to complete Offline
42data collection: ( 0) seconds.
43Offline data collection
44capabilities: (0x00) Offline data collection not supported.
45SMART capabilities: (0x0000) Automatic saving of SMART data is not implemented.
46Error logging capability: (0x00) Error logging supported.
47 General Purpose Logging supported.
48
49SMART Attributes Data Structure revision number: 64
50Vendor Specific SMART Attributes with Thresholds:
51ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
52255 Unknown_Attribute POSRCK+ 200 016 --- - 69269232549888
53 51 Unknown_Attribute POS-CK+ 049 052 --- - 52983541805108
54 57 Unknown_Attribute ---RCK 000 000 --- - 85019984920576
55 49 Unknown_Attribute P---CK+ 046 069 --- - 35323090390356
56 86 Unknown_Attribute P-S---+ 079 083 --- - 78276622295123
57 32 Unknown_Attribute -O----+ 032 032 --- - 35322350018592
58 32 Unknown_Attribute -----K+ 032 032 --- - 550026354720
59 16 Unknown_Attribute ------+ 000 016 --- - 193518609955836
60249 Unknown_Attribute P-SR-- 000 007 --- - 131943408599808
61120 Unknown_Attribute ------+ 000 000 --- - 31
62 64 Unknown_Attribute ------+ 015 000 --- - 109388546468608
63105 Unknown_Attribute --S-CK+ 188 099 --- - 32985518735169
64 1 Raw_Read_Error_Rate ------ 000 000 011 NOW 0
65 ||||||_ K auto-keep
66 |||||__ C event count
67 ||||___ R error rate
68 |||____ S speed/performance
69 ||_____ O updated online
70 |______ P prefailure warning
71
72General Purpose Log Directory Version 1
73SMART Log Directory Version 80
74Address Access R/W Size Description
750x00 GPL,SL R/O 1 Log Directory
760x01 GPL R/O 1 Summary SMART error log
770x02 GPL R/O 51 Comprehensive SMART error log
780x03 SL R/O 79 Ext. Comprehensive SMART error log
790x04 GPL R/O 8 Device Statistics log
800x04 SL R/O 194 Device Statistics log
810x05 SL R/O 160 Reserved for CFA
820x06 GPL R/O 1 SMART self-test log
830x09 GPL R/W 1 Selective self-test log
840x30 GPL R/O 9 IDENTIFY DEVICE data log
850x80-0x9f GPL R/W 16 Host vendor specific log
86
87SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
88
89SMART Error Log not supported
90
91SMART Extended Self-test Log (GP Log 0x07) not supported
92
93SMART Self-test Log not supported
94
95Selective Self-tests/Logging not supported
96
97SCT Commands not supported
98
99Device Statistics (GP Log 0x04)
100Page Offset Size Value Flags Description
1010x01 ===== = = === == General Statistics (empty) ==
102 |||_ C monitored condition met
103 ||__ D supports DSN
104 |___ N normalized value
105
106Pending Defects log (GP Log 0x0c) not supported
107
108Warning! SATA Phy Event Counters error: invalid SMART checksum.
109SATA Phy Event Counters (GP Log 0x11)
110[Reserved: 0x01 0x00 0x01 0x00]
111ID Size Value Description
112