Ticket #1332: SSDSA2BW160G3H-after.txt

File SSDSA2BW160G3H-after.txt, 6.4 KB (added by Christopher Alexander Chavez, 4 years ago)

smartctl -x after patching drivedb.h for HP OEM Intel 320 SSD

Line 
1smartctl 7.1 2019-12-30 r5022 [Darwin 19.4.0 x86_64] (local build)
2Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Model Family: Intel 320 Series SSDs
6Device Model: INTEL SSDSA2BW160G3H
7Serial Number: CVPR14530EKE160DGN
8LU WWN Device Id: 5 001517 bb27268a2
9Firmware Version: 4PC10365
10User Capacity: 160,041,885,696 bytes [160 GB]
11Sector Size: 512 bytes logical/physical
12Rotation Rate: Solid State Device
13Device is: In smartctl database [for details use: -P show]
14ATA Version is: ATA8-ACS T13/1699-D revision 4
15SATA Version is: SATA 2.6, 3.0 Gb/s
16Local Time is: Thu May 14 01:07:00 2020 CDT
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is: Unavailable
20APM feature is: Unavailable
21Rd look-ahead is: Enabled
22Write cache is: Enabled
23DSN feature is: Unavailable
24ATA Security is: Disabled, frozen [SEC2]
25Unexpected SCT status 0x0002 (action_code=4, function_code=2)
26Wt Cache Reorder: Unknown (SCT Feature Control command failed)
27
28=== START OF READ SMART DATA SECTION ===
29SMART overall-health self-assessment test result: PASSED
30
31General SMART Values:
32Offline data collection status: (0x00) Offline data collection activity
33 was never started.
34 Auto Offline Data Collection: Disabled.
35Self-test execution status: ( 0) The previous self-test routine completed
36 without error or no self-test has ever
37 been run.
38Total time to complete Offline
39data collection: ( 1) seconds.
40Offline data collection
41capabilities: (0x75) SMART execute Offline immediate.
42 No Auto Offline data collection support.
43 Abort Offline collection upon new
44 command.
45 No Offline surface scan supported.
46 Self-test supported.
47 Conveyance Self-test supported.
48 Selective Self-test supported.
49SMART capabilities: (0x0003) Saves SMART data before entering
50 power-saving mode.
51 Supports SMART auto save timer.
52Error logging capability: (0x01) Error logging supported.
53 General Purpose Logging supported.
54Short self-test routine
55recommended polling time: ( 1) minutes.
56Extended self-test routine
57recommended polling time: ( 22) minutes.
58Conveyance self-test routine
59recommended polling time: ( 1) minutes.
60SCT capabilities: (0x003d) SCT Status supported.
61 SCT Error Recovery Control supported.
62 SCT Feature Control supported.
63 SCT Data Table supported.
64
65SMART Attributes Data Structure revision number: 5
66Vendor Specific SMART Attributes with Thresholds:
67ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
68 3 Spin_Up_Time -----K 100 100 000 - 0
69 4 Start_Stop_Count ----CK 100 100 000 - 0
70 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
71 9 Power_On_Hours -O--CK 100 100 000 - 3946
72 12 Power_Cycle_Count -O--CK 100 100 000 - 2621
73170 Reserve_Block_Count PO--CK 100 100 010 - 0
74171 Program_Fail_Count -O--CK 100 100 000 - 0
75172 Erase_Fail_Count -O--CK 100 100 000 - 0
76183 SATA_Downshift_Count -O--CK 100 100 010 - 0
77184 End-to-End_Error PO--CK 100 100 097 - 0
78187 Reported_Uncorrect -O--CK 100 100 000 - 0
79192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 28
80199 CRC_Error_Count -OS-CK 100 100 000 - 0
81225 Host_Writes_32MiB -O--CK 100 100 000 - 233561
82226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 65535
83227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 65535
84228 Workload_Minutes -O--CK 100 100 000 - 65535
85232 Available_Reservd_Space PO--CK 100 100 010 - 0
86233 Media_Wearout_Indicator -O--CK 099 099 000 - 0
87241 Host_Writes_32MiB -O--CK 100 100 000 - 233561
88242 Host_Reads_32MiB -O--CK 100 100 000 - 269467
89 ||||||_ K auto-keep
90 |||||__ C event count
91 ||||___ R error rate
92 |||____ S speed/performance
93 ||_____ O updated online
94 |______ P prefailure warning
95
96Log Directories not read due to '-F nologdir' option
97
98ATA_READ_LOG_EXT (addr=0x03:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
99Read SMART Extended Comprehensive Error Log failed
100
101SMART Error Log Version: 1
102No Errors Logged
103
104ATA_READ_LOG_EXT (addr=0x07:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
105Read SMART Extended Self-test Log failed
106
107SMART Self-test log structure revision number 1
108Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
109# 1 Extended offline Completed without error 00% 3946 -
110# 2 Extended offline Completed without error 00% 3946 -
111# 3 Short offline Completed without error 00% 241 -
112# 4 Short offline Completed without error 00% 241 -
113
114SMART Selective self-test log data structure revision number 0
115Note: revision number not 1 implies that no selective self-test has ever been run
116 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
117 1 0 0 Not_testing
118 2 0 0 Not_testing
119 3 0 0 Not_testing
120 4 0 0 Not_testing
121 5 0 0 Not_testing
122Selective self-test flags (0x0):
123 After scanning selected spans, do NOT read-scan remainder of disk.
124If Selective self-test is pending on power-up, resume after 0 minute delay.
125
126SCT Status Version: 3
127SCT Version (vendor specific): 1 (0x0001)
128Device State: Active (0)
129Current Temperature: ? Celsius
130Power Cycle Min/Max Temperature: ?/ ? Celsius
131Lifetime Min/Max Temperature: ?/ ? Celsius
132Under/Over Temperature Limit Count: 0/0
133
134Read SCT Data Table failed: Undefined error: 0
135Read SCT Temperature History failed
136
137SMART WRITE LOG does not return COUNT and LBA_LOW register
138SCT (Get) Error Recovery Control command failed
139
140ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
141Read Device Statistics page 0x00 failed
142
143Pending Defects log (GP Log 0x0c) not supported
144
145ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
146Read SATA Phy Event Counters failed