Ticket #1332: SSDSA2BW160G3H-after.txt

File SSDSA2BW160G3H-after.txt, 6.4 KB (added by Christopher Alexander Chavez, 4 years ago)

smartctl -x after patching drivedb.h for HP OEM Intel 320 SSD

Line 
1smartctl 7.1 2019-12-30 r5022 [Darwin 19.4.0 x86_64] (local build)
2Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Model Family:     Intel 320 Series SSDs
6Device Model:     INTEL SSDSA2BW160G3H
7Serial Number:    CVPR14530EKE160DGN
8LU WWN Device Id: 5 001517 bb27268a2
9Firmware Version: 4PC10365
10User Capacity:    160,041,885,696 bytes [160 GB]
11Sector Size:      512 bytes logical/physical
12Rotation Rate:    Solid State Device
13Device is:        In smartctl database [for details use: -P show]
14ATA Version is:   ATA8-ACS T13/1699-D revision 4
15SATA Version is:  SATA 2.6, 3.0 Gb/s
16Local Time is:    Thu May 14 01:07:00 2020 CDT
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is:   Unavailable
20APM feature is:   Unavailable
21Rd look-ahead is: Enabled
22Write cache is:   Enabled
23DSN feature is:   Unavailable
24ATA Security is:  Disabled, frozen [SEC2]
25Unexpected SCT status 0x0002 (action_code=4, function_code=2)
26Wt Cache Reorder: Unknown (SCT Feature Control command failed)
27
28=== START OF READ SMART DATA SECTION ===
29SMART overall-health self-assessment test result: PASSED
30
31General SMART Values:
32Offline data collection status:  (0x00) Offline data collection activity
33                                        was never started.
34                                        Auto Offline Data Collection: Disabled.
35Self-test execution status:      (   0) The previous self-test routine completed
36                                        without error or no self-test has ever
37                                        been run.
38Total time to complete Offline
39data collection:                (    1) seconds.
40Offline data collection
41capabilities:                    (0x75) SMART execute Offline immediate.
42                                        No Auto Offline data collection support.
43                                        Abort Offline collection upon new
44                                        command.
45                                        No Offline surface scan supported.
46                                        Self-test supported.
47                                        Conveyance Self-test supported.
48                                        Selective Self-test supported.
49SMART capabilities:            (0x0003) Saves SMART data before entering
50                                        power-saving mode.
51                                        Supports SMART auto save timer.
52Error logging capability:        (0x01) Error logging supported.
53                                        General Purpose Logging supported.
54Short self-test routine
55recommended polling time:        (   1) minutes.
56Extended self-test routine
57recommended polling time:        (  22) minutes.
58Conveyance self-test routine
59recommended polling time:        (   1) minutes.
60SCT capabilities:              (0x003d) SCT Status supported.
61                                        SCT Error Recovery Control supported.
62                                        SCT Feature Control supported.
63                                        SCT Data Table supported.
64
65SMART Attributes Data Structure revision number: 5
66Vendor Specific SMART Attributes with Thresholds:
67ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
68  3 Spin_Up_Time            -----K   100   100   000    -    0
69  4 Start_Stop_Count        ----CK   100   100   000    -    0
70  5 Reallocated_Sector_Ct   -O--CK   100   100   000    -    0
71  9 Power_On_Hours          -O--CK   100   100   000    -    3946
72 12 Power_Cycle_Count       -O--CK   100   100   000    -    2621
73170 Reserve_Block_Count     PO--CK   100   100   010    -    0
74171 Program_Fail_Count      -O--CK   100   100   000    -    0
75172 Erase_Fail_Count        -O--CK   100   100   000    -    0
76183 SATA_Downshift_Count    -O--CK   100   100   010    -    0
77184 End-to-End_Error        PO--CK   100   100   097    -    0
78187 Reported_Uncorrect      -O--CK   100   100   000    -    0
79192 Unsafe_Shutdown_Count   -O--CK   100   100   000    -    28
80199 CRC_Error_Count         -OS-CK   100   100   000    -    0
81225 Host_Writes_32MiB       -O--CK   100   100   000    -    233561
82226 Workld_Media_Wear_Indic -O--CK   100   100   000    -    65535
83227 Workld_Host_Reads_Perc  -O--CK   100   100   000    -    65535
84228 Workload_Minutes        -O--CK   100   100   000    -    65535
85232 Available_Reservd_Space PO--CK   100   100   010    -    0
86233 Media_Wearout_Indicator -O--CK   099   099   000    -    0
87241 Host_Writes_32MiB       -O--CK   100   100   000    -    233561
88242 Host_Reads_32MiB        -O--CK   100   100   000    -    269467
89                            ||||||_ K auto-keep
90                            |||||__ C event count
91                            ||||___ R error rate
92                            |||____ S speed/performance
93                            ||_____ O updated online
94                            |______ P prefailure warning
95
96Log Directories not read due to '-F nologdir' option
97
98ATA_READ_LOG_EXT (addr=0x03:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
99Read SMART Extended Comprehensive Error Log failed
100
101SMART Error Log Version: 1
102No Errors Logged
103
104ATA_READ_LOG_EXT (addr=0x07:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
105Read SMART Extended Self-test Log failed
106
107SMART Self-test log structure revision number 1
108Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
109# 1  Extended offline    Completed without error       00%      3946         -
110# 2  Extended offline    Completed without error       00%      3946         -
111# 3  Short offline       Completed without error       00%       241         -
112# 4  Short offline       Completed without error       00%       241         -
113
114SMART Selective self-test log data structure revision number 0
115Note: revision number not 1 implies that no selective self-test has ever been run
116 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
117    1        0        0  Not_testing
118    2        0        0  Not_testing
119    3        0        0  Not_testing
120    4        0        0  Not_testing
121    5        0        0  Not_testing
122Selective self-test flags (0x0):
123  After scanning selected spans, do NOT read-scan remainder of disk.
124If Selective self-test is pending on power-up, resume after 0 minute delay.
125
126SCT Status Version:                  3
127SCT Version (vendor specific):       1 (0x0001)
128Device State:                        Active (0)
129Current Temperature:                     ? Celsius
130Power Cycle Min/Max Temperature:      ?/ ? Celsius
131Lifetime    Min/Max Temperature:      ?/ ? Celsius
132Under/Over Temperature Limit Count:   0/0
133
134Read SCT Data Table failed: Undefined error: 0
135Read SCT Temperature History failed
136
137SMART WRITE LOG does not return COUNT and LBA_LOW register
138SCT (Get) Error Recovery Control command failed
139
140ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
141Read Device Statistics page 0x00 failed
142
143Pending Defects log (GP Log 0x0c) not supported
144
145ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
146Read SATA Phy Event Counters failed