Ticket #1303: smartctl_scsiioctl_ssize.txt

File smartctl_scsiioctl_ssize.txt, 3.1 KB (added by yhemery, 4 years ago)

smartctl -r scsiioctl -i /dev/sg22

Line 
1smartctl 7.2 2020-01-11 r5029 [x86_64-linux-4.19.84-mod-std-ipv6-64-rescue] (local build)
2Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
3
4>>>> do_scsi_cmnd_io: sg_io_ver=3
5 [inquiry: 12 00 00 00 24 00 ]
6 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
7 sg_info=0x0 sg_duration=0 milliseconds resid=0
8>>>> do_scsi_cmnd_io: sg_io_ver=3
9 [inquiry: 12 01 00 00 fc 00 ]
10 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
11 sg_info=0x0 sg_duration=0 milliseconds resid=232
12>>>> do_scsi_cmnd_io: sg_io_ver=3
13 [inquiry: 12 00 00 00 24 00 ]
14 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
15 sg_info=0x0 sg_duration=0 milliseconds resid=0
16=== START OF INFORMATION SECTION ===
17Vendor: HGST
18Product: HUSMR3240ASS201
19Revision: B170
20Compliance: SPC-4
21>>>> do_scsi_cmnd_io: sg_io_ver=3
22 [read capacity(16): 9e 10 00 00 00 00 00 00 00 00 00 00 00 20 00 00 ]
23 scsi_status=0x2, sg_transport_status=0x0, sg_driver_status=0x8
24 sg_info=0x1 sg_duration=4 milliseconds resid=32
25 status=2: sense_key=6 asc=29 ascq=3
26scsiGetSize: READ CAPACITY(16) failed, res=8
27>>>> do_scsi_cmnd_io: sg_io_ver=3
28 [read capacity(10): 25 00 00 00 00 00 00 00 00 00 ]
29 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
30 sg_info=0x0 sg_duration=0 milliseconds resid=0
31User Capacity: 400,088,457,216 bytes [400 GB]
32Logical block size: 512 bytes
33>>>> do_scsi_cmnd_io: sg_io_ver=3
34 [inquiry: 12 01 b2 00 08 00 ]
35 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
36 sg_info=0x0 sg_duration=0 milliseconds resid=0
37LU is resource provisioned, LBPRZ=1
38>>>> do_scsi_cmnd_io: sg_io_ver=3
39 [inquiry: 12 01 b1 00 40 00 ]
40 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
41 sg_info=0x0 sg_duration=0 milliseconds resid=0
42Rotation Rate: Solid State Device
43Form Factor: 2.5 inches
44>>>> do_scsi_cmnd_io: sg_io_ver=3
45 [mode sense(6): 1a 00 1c 00 40 00 ]
46 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
47 sg_info=0x0 sg_duration=0 milliseconds resid=40
48>>>> do_scsi_cmnd_io: sg_io_ver=3
49 [mode sense(6): 1a 00 5c 00 40 00 ]
50 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
51 sg_info=0x0 sg_duration=0 milliseconds resid=40
52>>>> do_scsi_cmnd_io: sg_io_ver=3
53 [inquiry: 12 01 83 00 fc 00 ]
54 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
55 sg_info=0x0 sg_duration=0 milliseconds resid=176
56Logical Unit id: 0x5000cca09e05cef0
57>>>> do_scsi_cmnd_io: sg_io_ver=3
58 [inquiry: 12 01 80 00 fc 00 ]
59 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
60 sg_info=0x0 sg_duration=0 milliseconds resid=232
61Serial number: 73V360UX
62Device type: disk
63Transport protocol: SAS (SPL-3)
64Local Time is: Mon Feb 24 19:19:19 2020 CET
65>>>> do_scsi_cmnd_io: sg_io_ver=3
66 [test unit ready: 00 00 00 00 00 00 ]
67 scsi_status=0x0, sg_transport_status=0x0, sg_driver_status=0x0
68 sg_info=0x0 sg_duration=0 milliseconds resid=0
69SMART support is: Available - device has SMART capability.
70SMART support is: Enabled
71Temperature Warning: Enabled
72