| 1 | smartctl 6.6 2017-11-05 r4594 [x86_64-linux-5.2.0-2-amd64] (local build)
|
|---|
| 2 | Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Device Model: SanDisk SD8SBAT128G1002
|
|---|
| 6 | Firmware Version: Z2317002
|
|---|
| 7 | User Capacity: 128,035,676,160 bytes [128 GB]
|
|---|
| 8 | Sector Size: 512 bytes logical/physical
|
|---|
| 9 | Rotation Rate: Solid State Device
|
|---|
| 10 | Form Factor: 2.5 inches
|
|---|
| 11 | Device is: Not in smartctl database [for details use: -P showall]
|
|---|
| 12 | ATA Version is: ACS-2 T13/2015-D revision 3
|
|---|
| 13 | SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
|---|
| 14 | Local Time is: Sun Sep 1 23:48:46 2019 CST
|
|---|
| 15 | SMART support is: Available - device has SMART capability.
|
|---|
| 16 | SMART support is: Enabled
|
|---|
| 17 | AAM feature is: Unavailable
|
|---|
| 18 | APM level is: 254 (maximum performance)
|
|---|
| 19 | Rd look-ahead is: Enabled
|
|---|
| 20 | Write cache is: Enabled
|
|---|
| 21 | DSN feature is: Unavailable
|
|---|
| 22 | ATA Security is: Disabled, NOT FROZEN [SEC1]
|
|---|
| 23 | Wt Cache Reorder: Unavailable
|
|---|
| 24 |
|
|---|
| 25 | === START OF READ SMART DATA SECTION ===
|
|---|
| 26 | SMART overall-health self-assessment test result: PASSED
|
|---|
| 27 |
|
|---|
| 28 | General SMART Values:
|
|---|
| 29 | Offline data collection status: (0x00) Offline data collection activity
|
|---|
| 30 | was never started.
|
|---|
| 31 | Auto Offline Data Collection: Disabled.
|
|---|
| 32 | Self-test execution status: ( 0) The previous self-test routine completed
|
|---|
| 33 | without error or no self-test has ever
|
|---|
| 34 | been run.
|
|---|
| 35 | Total time to complete Offline
|
|---|
| 36 | data collection: ( 120) seconds.
|
|---|
| 37 | Offline data collection
|
|---|
| 38 | capabilities: (0x11) SMART execute Offline immediate.
|
|---|
| 39 | No Auto Offline data collection support.
|
|---|
| 40 | Suspend Offline collection upon new
|
|---|
| 41 | command.
|
|---|
| 42 | No Offline surface scan supported.
|
|---|
| 43 | Self-test supported.
|
|---|
| 44 | No Conveyance Self-test supported.
|
|---|
| 45 | No Selective Self-test supported.
|
|---|
| 46 | SMART capabilities: (0x0002) Does not save SMART data before
|
|---|
| 47 | entering power-saving mode.
|
|---|
| 48 | Supports SMART auto save timer.
|
|---|
| 49 | Error logging capability: (0x01) Error logging supported.
|
|---|
| 50 | General Purpose Logging supported.
|
|---|
| 51 | Short self-test routine
|
|---|
| 52 | recommended polling time: ( 2) minutes.
|
|---|
| 53 | Extended self-test routine
|
|---|
| 54 | recommended polling time: ( 10) minutes.
|
|---|
| 55 |
|
|---|
| 56 | SMART Attributes Data Structure revision number: 1
|
|---|
| 57 | Vendor Specific SMART Attributes with Thresholds:
|
|---|
| 58 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|---|
| 59 | 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
|
|---|
| 60 | 9 Power_On_Hours -O--CK 229 100 000 - 229
|
|---|
| 61 | 12 Power_Cycle_Count -O--CK 100 100 000 - 3769
|
|---|
| 62 | 166 Unknown_Attribute -O--CK 100 100 000 - 107
|
|---|
| 63 | 167 Unknown_Attribute -O--CK 100 100 000 - 0
|
|---|
| 64 | 168 Unknown_Attribute -O--CK 100 100 000 - 162
|
|---|
| 65 | 169 Unknown_Attribute -O--CK 100 100 000 - 116
|
|---|
| 66 | 170 Unknown_Attribute -O--CK 100 100 000 - 0
|
|---|
| 67 | 171 Unknown_Attribute -O--CK 100 100 000 - 0
|
|---|
| 68 | 172 Unknown_Attribute -O--CK 100 100 000 - 0
|
|---|
| 69 | 173 Unknown_Attribute -O--CK 100 100 --- - 140
|
|---|
| 70 | 174 Unknown_Attribute -O--CK 100 100 000 - 203
|
|---|
| 71 | 187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
|---|
| 72 | 194 Temperature_Celsius -O---K 079 100 000 - 21 (Min/Max 0/50)
|
|---|
| 73 | 199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 4
|
|---|
| 74 | 230 Unknown_SSD_Attribute -O--CK 100 100 000 - 1320
|
|---|
| 75 | 232 Available_Reservd_Space PO--CK 100 100 004 - 100
|
|---|
| 76 | 233 Media_Wearout_Indicator -O--CK 100 100 000 - 12261
|
|---|
| 77 | 241 Total_LBAs_Written ----CK 253 253 000 - 2177
|
|---|
| 78 | 242 Total_LBAs_Read ----CK 253 253 000 - 2324
|
|---|
| 79 | ||||||_ K auto-keep
|
|---|
| 80 | |||||__ C event count
|
|---|
| 81 | ||||___ R error rate
|
|---|
| 82 | |||____ S speed/performance
|
|---|
| 83 | ||_____ O updated online
|
|---|
| 84 | |______ P prefailure warning
|
|---|
| 85 |
|
|---|
| 86 | General Purpose Log Directory Version 1
|
|---|
| 87 | SMART Log Directory Version 1 [multi-sector log support]
|
|---|
| 88 | Address Access R/W Size Description
|
|---|
| 89 | 0x00 GPL,SL R/O 1 Log Directory
|
|---|
| 90 | 0x01 SL R/O 1 Summary SMART error log
|
|---|
| 91 | 0x02 SL R/O 1 Comprehensive SMART error log
|
|---|
| 92 | 0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
|---|
| 93 | 0x04 GPL,SL R/O 8 Device Statistics log
|
|---|
| 94 | 0x06 SL R/O 1 SMART self-test log
|
|---|
| 95 | 0x07 GPL R/O 1 Extended self-test log
|
|---|
| 96 | 0x10 GPL R/O 1 NCQ Command Error log
|
|---|
| 97 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
|---|
| 98 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
|---|
| 99 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|---|
| 100 |
|
|---|
| 101 | Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
|
|---|
| 102 | SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
|---|
| 103 | Device Error Count: 4
|
|---|
| 104 | CR = Command Register
|
|---|
| 105 | FEATR = Features Register
|
|---|
| 106 | COUNT = Count (was: Sector Count) Register
|
|---|
| 107 | LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
|---|
| 108 | LH = LBA High (was: Cylinder High) Register ] LBA
|
|---|
| 109 | LM = LBA Mid (was: Cylinder Low) Register ] Register
|
|---|
| 110 | LL = LBA Low (was: Sector Number) Register ]
|
|---|
| 111 | DV = Device (was: Device/Head) Register
|
|---|
| 112 | DC = Device Control Register
|
|---|
| 113 | ER = Error register
|
|---|
| 114 | ST = Status register
|
|---|
| 115 | Powered_Up_Time is measured from power on, and printed as
|
|---|
| 116 | DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|---|
| 117 | SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|---|
| 118 |
|
|---|
| 119 | Error 4 [3] occurred at disk power-on lifetime: 65535 hours (2730 days + 15 hours)
|
|---|
| 120 | When the command that caused the error occurred, the device was in a vendor specific state.
|
|---|
| 121 |
|
|---|
| 122 | After command completion occurred, registers were:
|
|---|
| 123 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|---|
| 124 | -- -- -- == -- == == == -- -- -- -- --
|
|---|
| 125 | ff -- ff ff ff ff ff ff ff ff ff ff ff
|
|---|
| 126 |
|
|---|
| 127 | Commands leading to the command that caused the error were:
|
|---|
| 128 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|---|
| 129 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|---|
| 130 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 131 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 132 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 133 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 134 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 135 |
|
|---|
| 136 | Error 3 [2] occurred at disk power-on lifetime: 65535 hours (2730 days + 15 hours)
|
|---|
| 137 | When the command that caused the error occurred, the device was in a vendor specific state.
|
|---|
| 138 |
|
|---|
| 139 | After command completion occurred, registers were:
|
|---|
| 140 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|---|
| 141 | -- -- -- == -- == == == -- -- -- -- --
|
|---|
| 142 | ff -- ff ff ff ff ff ff ff ff ff ff ff
|
|---|
| 143 |
|
|---|
| 144 | Commands leading to the command that caused the error were:
|
|---|
| 145 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|---|
| 146 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|---|
| 147 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 148 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 149 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 150 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 151 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 152 |
|
|---|
| 153 | Error 2 [1] occurred at disk power-on lifetime: 65535 hours (2730 days + 15 hours)
|
|---|
| 154 | When the command that caused the error occurred, the device was in a vendor specific state.
|
|---|
| 155 |
|
|---|
| 156 | After command completion occurred, registers were:
|
|---|
| 157 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|---|
| 158 | -- -- -- == -- == == == -- -- -- -- --
|
|---|
| 159 | ff -- ff ff ff ff ff ff ff ff ff ff ff
|
|---|
| 160 |
|
|---|
| 161 | Commands leading to the command that caused the error were:
|
|---|
| 162 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|---|
| 163 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|---|
| 164 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 165 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 166 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 167 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 168 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 169 |
|
|---|
| 170 | Error 1 [0] occurred at disk power-on lifetime: 65535 hours (2730 days + 15 hours)
|
|---|
| 171 | When the command that caused the error occurred, the device was in a vendor specific state.
|
|---|
| 172 |
|
|---|
| 173 | After command completion occurred, registers were:
|
|---|
| 174 | ER -- ST COUNT LBA_48 LH LM LL DV DC
|
|---|
| 175 | -- -- -- == -- == == == -- -- -- -- --
|
|---|
| 176 | ff -- ff ff ff ff ff ff ff ff ff ff ff
|
|---|
| 177 |
|
|---|
| 178 | Commands leading to the command that caused the error were:
|
|---|
| 179 | CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
|---|
| 180 | -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
|---|
| 181 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 182 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 183 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 184 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 185 | ff ff ff ff ff ff ff ff ff ff ff ff ff 49d+17:02:47.295 [VENDOR SPECIFIC]
|
|---|
| 186 |
|
|---|
| 187 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
|---|
| 188 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
|---|
| 189 | # 1 Short offline Completed without error 00% 229 -
|
|---|
| 190 |
|
|---|
| 191 | Selective Self-tests/Logging not supported
|
|---|
| 192 |
|
|---|
| 193 | SCT Commands not supported
|
|---|
| 194 |
|
|---|
| 195 | Device Statistics (GP Log 0x04)
|
|---|
| 196 | Page Offset Size Value Flags Description
|
|---|
| 197 | 0x01 ===== = = === == General Statistics (rev 1) ==
|
|---|
| 198 | 0x01 0x008 4 3769 --- Lifetime Power-On Resets
|
|---|
| 199 | 0x01 0x018 6 0 --- Logical Sectors Written
|
|---|
| 200 | 0x01 0x020 6 0 --- Number of Write Commands
|
|---|
| 201 | 0x01 0x028 6 0 --- Logical Sectors Read
|
|---|
| 202 | 0x01 0x030 6 0 --- Number of Read Commands
|
|---|
| 203 | 0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
|---|
| 204 | 0x07 0x008 1 4 --- Percentage Used Endurance Indicator
|
|---|
| 205 | |||_ C monitored condition met
|
|---|
| 206 | ||__ D supports DSN
|
|---|
| 207 | |___ N normalized value
|
|---|
| 208 |
|
|---|
| 209 | Pending Defects log (GP Log 0x0c) not supported
|
|---|
| 210 |
|
|---|
| 211 | SATA Phy Event Counters (GP Log 0x11)
|
|---|
| 212 | ID Size Value Description
|
|---|
| 213 | 0x0001 4 0 Command failed due to ICRC error
|
|---|
| 214 | 0x0002 4 0 R_ERR response for data FIS
|
|---|
| 215 | 0x0005 4 0 R_ERR response for non-data FIS
|
|---|
| 216 | 0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
|---|
| 217 |
|
|---|