1 | smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.0-137-generic] (local build)
|
---|
2 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: WDC WD121KRYZ-01W0RB0
|
---|
6 | Firmware Version: 01.01H01
|
---|
7 | User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
---|
8 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
---|
9 | Rotation Rate: 7200 rpm
|
---|
10 | Form Factor: 3.5 inches
|
---|
11 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
12 | ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4
|
---|
13 | SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
---|
14 | Local Time is: Mon Oct 22 18:12:10 2018 CDT
|
---|
15 | SMART support is: Available - device has SMART capability.
|
---|
16 | SMART support is: Enabled
|
---|
17 | AAM feature is: Unavailable
|
---|
18 | APM level is: 254 (maximum performance)
|
---|
19 | Rd look-ahead is: Enabled
|
---|
20 | Write cache is: Enabled
|
---|
21 | ATA Security is: Disabled, NOT FROZEN [SEC1]
|
---|
22 | Wt Cache Reorder: Enabled
|
---|
23 |
|
---|
24 | === START OF READ SMART DATA SECTION ===
|
---|
25 | SMART overall-health self-assessment test result: PASSED
|
---|
26 |
|
---|
27 | General SMART Values:
|
---|
28 | Offline data collection status: (0x80) Offline data collection activity
|
---|
29 | was never started.
|
---|
30 | Auto Offline Data Collection: Enabled.
|
---|
31 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
32 | without error or no self-test has ever
|
---|
33 | been run.
|
---|
34 | Total time to complete Offline
|
---|
35 | data collection: ( 87) seconds.
|
---|
36 | Offline data collection
|
---|
37 | capabilities: (0x5b) SMART execute Offline immediate.
|
---|
38 | Auto Offline data collection on/off support.
|
---|
39 | Suspend Offline collection upon new
|
---|
40 | command.
|
---|
41 | Offline surface scan supported.
|
---|
42 | Self-test supported.
|
---|
43 | No Conveyance Self-test supported.
|
---|
44 | Selective Self-test supported.
|
---|
45 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
46 | power-saving mode.
|
---|
47 | Supports SMART auto save timer.
|
---|
48 | Error logging capability: (0x01) Error logging supported.
|
---|
49 | General Purpose Logging supported.
|
---|
50 | Short self-test routine
|
---|
51 | recommended polling time: ( 2) minutes.
|
---|
52 | Extended self-test routine
|
---|
53 | recommended polling time: (1326) minutes.
|
---|
54 | SCT capabilities: (0x003d) SCT Status supported.
|
---|
55 | SCT Error Recovery Control supported.
|
---|
56 | SCT Feature Control supported.
|
---|
57 | SCT Data Table supported.
|
---|
58 |
|
---|
59 | SMART Attributes Data Structure revision number: 16
|
---|
60 | Vendor Specific SMART Attributes with Thresholds:
|
---|
61 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
---|
62 | 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
---|
63 | 2 Throughput_Performance P-S--- 100 100 054 - 0
|
---|
64 | 3 Spin_Up_Time POS--- 100 100 024 - 0
|
---|
65 | 4 Start_Stop_Count -O--C- 100 100 000 - 1
|
---|
66 | 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
---|
67 | 7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
---|
68 | 8 Seek_Time_Performance P-S--- 100 100 020 - 0
|
---|
69 | 9 Power_On_Hours -O--C- 100 100 000 - 1
|
---|
70 | 10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
---|
71 | 12 Power_Cycle_Count -O--CK 100 100 000 - 1
|
---|
72 | 22 Unknown_Attribute PO---K 100 100 025 - 100
|
---|
73 | 192 Power-Off_Retract_Count -O--CK 100 100 000 - 1
|
---|
74 | 193 Load_Cycle_Count -O--C- 100 100 000 - 1
|
---|
75 | 194 Temperature_Celsius -O---- 120 120 000 - 50 (Min/Max 24/50)
|
---|
76 | 196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
---|
77 | 197 Current_Pending_Sector -O---K 100 100 000 - 0
|
---|
78 | 198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
---|
79 | 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
---|
80 | ||||||_ K auto-keep
|
---|
81 | |||||__ C event count
|
---|
82 | ||||___ R error rate
|
---|
83 | |||____ S speed/performance
|
---|
84 | ||_____ O updated online
|
---|
85 | |______ P prefailure warning
|
---|
86 |
|
---|
87 | General Purpose Log Directory Version 1
|
---|
88 | SMART Log Directory Version 1 [multi-sector log support]
|
---|
89 | Address Access R/W Size Description
|
---|
90 | 0x00 GPL,SL R/O 1 Log Directory
|
---|
91 | 0x01 SL R/O 1 Summary SMART error log
|
---|
92 | 0x02 SL R/O 1 Comprehensive SMART error log
|
---|
93 | 0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
---|
94 | 0x04 GPL R/O 256 Device Statistics log
|
---|
95 | 0x04 SL R/O 255 Device Statistics log
|
---|
96 | 0x06 SL R/O 1 SMART self-test log
|
---|
97 | 0x07 GPL R/O 1 Extended self-test log
|
---|
98 | 0x08 GPL R/O 2 Power Conditions log
|
---|
99 | 0x09 SL R/W 1 Selective self-test log
|
---|
100 | 0x0c GPL R/O 5501 Pending Defects log
|
---|
101 | 0x10 GPL R/O 1 SATA NCQ Queued Error log
|
---|
102 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
---|
103 | 0x12 GPL R/O 1 SATA NCQ NON-DATA log
|
---|
104 | 0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
---|
105 | 0x15 GPL R/W 1 SATA Rebuild Assist log
|
---|
106 | 0x21 GPL R/O 1 Write stream error log
|
---|
107 | 0x22 GPL R/O 1 Read stream error log
|
---|
108 | 0x24 GPL R/O 256 Current Device Internal Status Data log
|
---|
109 | 0x25 GPL R/O 256 Saved Device Internal Status Data log
|
---|
110 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
---|
111 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
---|
112 | 0xe0 GPL,SL R/W 1 SCT Command/Status
|
---|
113 | 0xe1 GPL,SL R/W 1 SCT Data Transfer
|
---|
114 |
|
---|
115 | SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
---|
116 | No Errors Logged
|
---|
117 |
|
---|
118 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
---|
119 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
---|
120 | # 1 Short offline Completed without error 00% 1 -
|
---|
121 |
|
---|
122 | SMART Selective self-test log data structure revision number 1
|
---|
123 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
124 | 1 0 0 Not_testing
|
---|
125 | 2 0 0 Not_testing
|
---|
126 | 3 0 0 Not_testing
|
---|
127 | 4 0 0 Not_testing
|
---|
128 | 5 0 0 Not_testing
|
---|
129 | Selective self-test flags (0x0):
|
---|
130 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
131 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
132 |
|
---|
133 | SCT Status Version: 3
|
---|
134 | SCT Version (vendor specific): 256 (0x0100)
|
---|
135 | SCT Support Level: 0
|
---|
136 | Device State: Active (0)
|
---|
137 | Current Temperature: 50 Celsius
|
---|
138 | Power Cycle Min/Max Temperature: 24/50 Celsius
|
---|
139 | Lifetime Min/Max Temperature: 24/50 Celsius
|
---|
140 | Under/Over Temperature Limit Count: 0/0
|
---|
141 |
|
---|
142 | SCT Temperature History Version: 2
|
---|
143 | Temperature Sampling Period: 1 minute
|
---|
144 | Temperature Logging Interval: 1 minute
|
---|
145 | Min/Max recommended Temperature: 0/60 Celsius
|
---|
146 | Min/Max Temperature Limit: -40/70 Celsius
|
---|
147 | Temperature History Size (Index): 128 (66)
|
---|
148 |
|
---|
149 | Index Estimated Time Temperature Celsius
|
---|
150 | 67 2018-10-22 16:05 0 -
|
---|
151 | ... ..( 59 skipped). .. -
|
---|
152 | 127 2018-10-22 17:05 0 -
|
---|
153 | 0 2018-10-22 17:06 25 ******
|
---|
154 | 1 2018-10-22 17:07 25 ******
|
---|
155 | 2 2018-10-22 17:08 26 *******
|
---|
156 | 3 2018-10-22 17:09 27 ********
|
---|
157 | 4 2018-10-22 17:10 27 ********
|
---|
158 | 5 2018-10-22 17:11 28 *********
|
---|
159 | 6 2018-10-22 17:12 29 **********
|
---|
160 | 7 2018-10-22 17:13 29 **********
|
---|
161 | 8 2018-10-22 17:14 30 ***********
|
---|
162 | 9 2018-10-22 17:15 30 ***********
|
---|
163 | 10 2018-10-22 17:16 31 ************
|
---|
164 | 11 2018-10-22 17:17 31 ************
|
---|
165 | 12 2018-10-22 17:18 32 *************
|
---|
166 | 13 2018-10-22 17:19 32 *************
|
---|
167 | 14 2018-10-22 17:20 33 **************
|
---|
168 | 15 2018-10-22 17:21 33 **************
|
---|
169 | 16 2018-10-22 17:22 33 **************
|
---|
170 | 17 2018-10-22 17:23 34 ***************
|
---|
171 | 18 2018-10-22 17:24 34 ***************
|
---|
172 | 19 2018-10-22 17:25 35 ****************
|
---|
173 | 20 2018-10-22 17:26 35 ****************
|
---|
174 | 21 2018-10-22 17:27 35 ****************
|
---|
175 | 22 2018-10-22 17:28 36 *****************
|
---|
176 | 23 2018-10-22 17:29 36 *****************
|
---|
177 | 24 2018-10-22 17:30 36 *****************
|
---|
178 | 25 2018-10-22 17:31 37 ******************
|
---|
179 | 26 2018-10-22 17:32 37 ******************
|
---|
180 | 27 2018-10-22 17:33 37 ******************
|
---|
181 | 28 2018-10-22 17:34 38 *******************
|
---|
182 | 29 2018-10-22 17:35 38 *******************
|
---|
183 | 30 2018-10-22 17:36 38 *******************
|
---|
184 | 31 2018-10-22 17:37 39 ********************
|
---|
185 | 32 2018-10-22 17:38 39 ********************
|
---|
186 | 33 2018-10-22 17:39 39 ********************
|
---|
187 | 34 2018-10-22 17:40 40 *********************
|
---|
188 | ... ..( 2 skipped). .. *********************
|
---|
189 | 37 2018-10-22 17:43 40 *********************
|
---|
190 | 38 2018-10-22 17:44 41 **********************
|
---|
191 | ... ..( 2 skipped). .. **********************
|
---|
192 | 41 2018-10-22 17:47 41 **********************
|
---|
193 | 42 2018-10-22 17:48 42 ***********************
|
---|
194 | 43 2018-10-22 17:49 42 ***********************
|
---|
195 | 44 2018-10-22 17:50 42 ***********************
|
---|
196 | 45 2018-10-22 17:51 43 ************************
|
---|
197 | 46 2018-10-22 17:52 43 ************************
|
---|
198 | 47 2018-10-22 17:53 43 ************************
|
---|
199 | 48 2018-10-22 17:54 44 *************************
|
---|
200 | 49 2018-10-22 17:55 44 *************************
|
---|
201 | 50 2018-10-22 17:56 45 **************************
|
---|
202 | 51 2018-10-22 17:57 45 **************************
|
---|
203 | 52 2018-10-22 17:58 46 ***************************
|
---|
204 | 53 2018-10-22 17:59 46 ***************************
|
---|
205 | 54 2018-10-22 18:00 46 ***************************
|
---|
206 | 55 2018-10-22 18:01 47 ****************************
|
---|
207 | ... ..( 2 skipped). .. ****************************
|
---|
208 | 58 2018-10-22 18:04 47 ****************************
|
---|
209 | 59 2018-10-22 18:05 48 *****************************
|
---|
210 | 60 2018-10-22 18:06 48 *****************************
|
---|
211 | 61 2018-10-22 18:07 48 *****************************
|
---|
212 | 62 2018-10-22 18:08 49 ******************************
|
---|
213 | ... ..( 2 skipped). .. ******************************
|
---|
214 | 65 2018-10-22 18:11 49 ******************************
|
---|
215 | 66 2018-10-22 18:12 0 -
|
---|
216 |
|
---|
217 | SCT Error Recovery Control:
|
---|
218 | Read: Disabled
|
---|
219 | Write: Disabled
|
---|
220 |
|
---|
221 | Device Statistics (GP/SMART Log 0x04) not supported
|
---|
222 |
|
---|
223 | SATA Phy Event Counters (GP Log 0x11)
|
---|
224 | ID Size Value Description
|
---|
225 | 0x0001 2 0 Command failed due to ICRC error
|
---|
226 | 0x0002 2 0 R_ERR response for data FIS
|
---|
227 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
---|
228 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
---|
229 | 0x0005 2 0 R_ERR response for non-data FIS
|
---|
230 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
---|
231 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
---|
232 | 0x0008 2 0 Device-to-host non-data FIS retries
|
---|
233 | 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
|
---|
234 | 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
---|
235 | 0x000b 2 0 CRC errors within host-to-device FIS
|
---|
236 | 0x000d 2 0 Non-CRC errors within host-to-device FIS
|
---|
237 |
|
---|