1 | # smartctl -a /dev/sde |
---|
2 | smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.18-10-pve] (local build) |
---|
3 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org |
---|
4 | |
---|
5 | === START OF INFORMATION SECTION === |
---|
6 | Device Model: SuperMicro SSD |
---|
7 | Serial Number: SMC0515D90717B6J6896 |
---|
8 | LU WWN Device Id: 5 15d907 17b000896 |
---|
9 | Firmware Version: SOB20R |
---|
10 | User Capacity: 31,675,383,808 bytes [31.6 GB] |
---|
11 | Sector Size: 512 bytes logical/physical |
---|
12 | Rotation Rate: Solid State Device |
---|
13 | Device is: Not in smartctl database [for details use: -P showall] |
---|
14 | ATA Version is: ACS-2 (minor revision not indicated) |
---|
15 | SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) |
---|
16 | Local Time is: Mon Mar 11 13:41:22 2019 CET |
---|
17 | SMART support is: Available - device has SMART capability. |
---|
18 | SMART support is: Enabled |
---|
19 | |
---|
20 | === START OF READ SMART DATA SECTION === |
---|
21 | SMART overall-health self-assessment test result: PASSED |
---|
22 | |
---|
23 | General SMART Values: |
---|
24 | Offline data collection status: (0x00) Offline data collection activity |
---|
25 | was never started. |
---|
26 | Auto Offline Data Collection: Disabled. |
---|
27 | Self-test execution status: ( 0) The previous self-test routine completed |
---|
28 | without error or no self-test has ever |
---|
29 | been run. |
---|
30 | Total time to complete Offline |
---|
31 | data collection: ( 0) seconds. |
---|
32 | Offline data collection |
---|
33 | capabilities: (0x71) SMART execute Offline immediate. |
---|
34 | No Auto Offline data collection support. |
---|
35 | Suspend Offline collection upon new |
---|
36 | command. |
---|
37 | No Offline surface scan supported. |
---|
38 | Self-test supported. |
---|
39 | Conveyance Self-test supported. |
---|
40 | Selective Self-test supported. |
---|
41 | SMART capabilities: (0x0002) Does not save SMART data before |
---|
42 | entering power-saving mode. |
---|
43 | Supports SMART auto save timer. |
---|
44 | Error logging capability: (0x01) Error logging supported. |
---|
45 | General Purpose Logging supported. |
---|
46 | Short self-test routine |
---|
47 | recommended polling time: ( 2) minutes. |
---|
48 | Extended self-test routine |
---|
49 | recommended polling time: ( 10) minutes. |
---|
50 | Conveyance self-test routine |
---|
51 | recommended polling time: ( 2) minutes. |
---|
52 | |
---|
53 | SMART Attributes Data Structure revision number: 1 |
---|
54 | Vendor Specific SMART Attributes with Thresholds: |
---|
55 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE |
---|
56 | 1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline - 0 |
---|
57 | 5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline - 0 |
---|
58 | 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 7830 |
---|
59 | 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 14 |
---|
60 | 15 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 61865984 |
---|
61 | 160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 |
---|
62 | 161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 162 |
---|
63 | 163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 11 |
---|
64 | 164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 55249 |
---|
65 | 165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 131 |
---|
66 | 166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 4 |
---|
67 | 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 26 |
---|
68 | 168 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3000 |
---|
69 | 172 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 |
---|
70 | 175 Program_Fail_Count_Chip 0x0000 100 100 000 Old_age Offline - 11 |
---|
71 | 177 Wear_Leveling_Count 0x0000 100 100 000 Old_age Offline - 2 |
---|
72 | 181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline - 0 |
---|
73 | 187 Reported_Uncorrect 0x0000 100 100 000 Old_age Offline - 0 |
---|
74 | 192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline - 1 |
---|
75 | 194 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 34 (Min/Max 19/50) |
---|
76 | 195 Hardware_ECC_Recovered 0x0000 100 100 000 Old_age Offline - 5499 |
---|
77 | 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 0 |
---|
78 | 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 |
---|
79 | 199 UDMA_CRC_Error_Count 0x0000 100 100 000 Old_age Offline - 78 |
---|
80 | 231 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 100 |
---|
81 | 232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline - 100 |
---|
82 | 233 Media_Wearout_Indicator 0x0000 100 100 000 Old_age Offline - 863 |
---|
83 | 241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline - 370 |
---|
84 | 242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline - 222 |
---|
85 | |
---|
86 | SMART Error Log Version: 1 |
---|
87 | No Errors Logged |
---|
88 | |
---|
89 | SMART Self-test log structure revision number 1 |
---|
90 | No self-tests have been logged. [To run self-tests, use: smartctl -t] |
---|
91 | |
---|
92 | SMART Selective self-test log data structure revision number 1 |
---|
93 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS |
---|
94 | 1 0 0 Not_testing |
---|
95 | 2 0 0 Not_testing |
---|
96 | 3 0 0 Not_testing |
---|
97 | 4 0 0 Not_testing |
---|
98 | 5 0 0 Not_testing |
---|
99 | Selective self-test flags (0x0): |
---|
100 | After scanning selected spans, do NOT read-scan remainder of disk. |
---|
101 | If Selective self-test is pending on power-up, resume after 0 minute delay. |
---|
102 | |
---|