1 | >smartctl -a /dev/da0 -d sat |
---|
2 | smartctl 6.3 2014-07-26 r3976 [NS-BSD 2.7.4- amd64] (local build) |
---|
3 | Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org |
---|
4 | |
---|
5 | === START OF INFORMATION SECTION === |
---|
6 | Device Model: SanDisk SD9SB8W1T001122 |
---|
7 | Serial Number: 1823AA800732 |
---|
8 | LU WWN Device Id: 5 001b44 8b6dc84d3 |
---|
9 | Firmware Version: X6107000 |
---|
10 | User Capacity: 1,024,209,543,168 bytes [1,02 TB] |
---|
11 | Sector Size: 512 bytes logical/physical |
---|
12 | Rotation Rate: Solid State Device |
---|
13 | Form Factor: 2.5 inches |
---|
14 | Device is: Not in smartctl database [for details use: -P showall] |
---|
15 | ATA Version is: Unknown(0x0ff0) (unknown minor revision code: 0x005e) |
---|
16 | SATA Version is: SATA >3.1, 6.0 Gb/s (current: 6.0 Gb/s) |
---|
17 | Local Time is: Fri Jan 18 14:57:08 2019 UTC |
---|
18 | SMART support is: Available - device has SMART capability. |
---|
19 | SMART support is: Enabled |
---|
20 | |
---|
21 | === START OF READ SMART DATA SECTION === |
---|
22 | SMART Status not supported: Incomplete response, ATA output registers missing |
---|
23 | SMART overall-health self-assessment test result: PASSED |
---|
24 | Warning: This result is based on an Attribute check. |
---|
25 | |
---|
26 | General SMART Values: |
---|
27 | Offline data collection status: (0x00) Offline data collection activity |
---|
28 | was never started. |
---|
29 | Auto Offline Data Collection: Disabled. |
---|
30 | Self-test execution status: ( 0) The previous self-test routine completed |
---|
31 | without error or no self-test has ever |
---|
32 | been run. |
---|
33 | Total time to complete Offline |
---|
34 | data collection: ( 0) seconds. |
---|
35 | Offline data collection |
---|
36 | capabilities: (0x11) SMART execute Offline immediate. |
---|
37 | No Auto Offline data collection support. |
---|
38 | Suspend Offline collection upon new |
---|
39 | command. |
---|
40 | No Offline surface scan supported. |
---|
41 | Self-test supported. |
---|
42 | No Conveyance Self-test supported. |
---|
43 | No Selective Self-test supported. |
---|
44 | SMART capabilities: (0x0003) Saves SMART data before entering |
---|
45 | power-saving mode. |
---|
46 | Supports SMART auto save timer. |
---|
47 | Error logging capability: (0x01) Error logging supported. |
---|
48 | General Purpose Logging supported. |
---|
49 | Short self-test routine |
---|
50 | recommended polling time: ( 2) minutes. |
---|
51 | Extended self-test routine |
---|
52 | recommended polling time: ( 10) minutes. |
---|
53 | |
---|
54 | SMART Attributes Data Structure revision number: 4 |
---|
55 | Vendor Specific SMART Attributes with Thresholds: |
---|
56 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE |
---|
57 | 5 Reallocated_Sector_Ct 0x0032 100 100 --- Old_age Always - 0 |
---|
58 | 9 Power_On_Hours 0x0032 100 100 --- Old_age Always - 5 |
---|
59 | 12 Power_Cycle_Count 0x0032 100 100 --- Old_age Always - 5 |
---|
60 | 165 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
61 | 166 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
62 | 167 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 112 |
---|
63 | 168 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
64 | 169 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 853 |
---|
65 | 170 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
66 | 171 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
67 | 172 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
68 | 173 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
69 | 174 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 1 |
---|
70 | 184 End-to-End_Error 0x0032 100 100 --- Old_age Always - 0 |
---|
71 | 187 Reported_Uncorrect 0x0032 100 100 --- Old_age Always - 0 |
---|
72 | 188 Command_Timeout 0x0032 100 100 --- Old_age Always - 0 |
---|
73 | 194 Temperature_Celsius 0x0022 074 038 --- Old_age Always - 26 (Min/Max 24/38) |
---|
74 | 199 UDMA_CRC_Error_Count 0x0032 100 100 --- Old_age Always - 0 |
---|
75 | 230 Unknown_SSD_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
76 | 232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 100 |
---|
77 | 233 Media_Wearout_Indicator 0x0032 100 100 --- Old_age Always - 0 |
---|
78 | 234 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 0 |
---|
79 | 241 Total_LBAs_Written 0x0030 253 253 --- Old_age Offline - 0 |
---|
80 | 242 Total_LBAs_Read 0x0030 253 253 --- Old_age Offline - 0 |
---|
81 | 244 Unknown_Attribute 0x0032 000 100 --- Old_age Always - 0 |
---|
82 | |
---|
83 | SMART Error Log Version: 1 |
---|
84 | No Errors Logged |
---|
85 | |
---|
86 | SMART Self-test log structure revision number 1 |
---|
87 | No self-tests have been logged. [To run self-tests, use: smartctl -t] |
---|
88 | |
---|
89 | Selective Self-tests/Logging not supported |
---|
90 | |
---|