| 1 | smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-22-generic] (local build)
|
|---|
| 2 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Device Model: WDC WD5000AZRX-00A8LB0
|
|---|
| 6 | Firmware Version: 01.01A01
|
|---|
| 7 | User Capacity: 500 107 862 016 bytes [500 GB]
|
|---|
| 8 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
|---|
| 9 | Device is: Not in smartctl database [for details use: -P showall]
|
|---|
| 10 | ATA Version is: ATA8-ACS (minor revision not indicated)
|
|---|
| 11 | SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
|---|
| 12 | Local Time is: Mon Jun 11 20:18:40 2018 MSK
|
|---|
| 13 | SMART support is: Available - device has SMART capability.
|
|---|
| 14 | SMART support is: Enabled
|
|---|
| 15 | AAM feature is: Unavailable
|
|---|
| 16 | APM feature is: Unavailable
|
|---|
| 17 | Rd look-ahead is: Enabled
|
|---|
| 18 | Write cache is: Enabled
|
|---|
| 19 | ATA Security is: Disabled, NOT FROZEN [SEC1]
|
|---|
| 20 | Wt Cache Reorder: Enabled
|
|---|
| 21 |
|
|---|
| 22 | === START OF READ SMART DATA SECTION ===
|
|---|
| 23 | SMART overall-health self-assessment test result: PASSED
|
|---|
| 24 |
|
|---|
| 25 | General SMART Values:
|
|---|
| 26 | Offline data collection status: (0x82) Offline data collection activity
|
|---|
| 27 | was completed without error.
|
|---|
| 28 | Auto Offline Data Collection: Enabled.
|
|---|
| 29 | Self-test execution status: ( 0) The previous self-test routine completed
|
|---|
| 30 | without error or no self-test has ever
|
|---|
| 31 | been run.
|
|---|
| 32 | Total time to complete Offline
|
|---|
| 33 | data collection: ( 8160) seconds.
|
|---|
| 34 | Offline data collection
|
|---|
| 35 | capabilities: (0x7b) SMART execute Offline immediate.
|
|---|
| 36 | Auto Offline data collection on/off support.
|
|---|
| 37 | Suspend Offline collection upon new
|
|---|
| 38 | command.
|
|---|
| 39 | Offline surface scan supported.
|
|---|
| 40 | Self-test supported.
|
|---|
| 41 | Conveyance Self-test supported.
|
|---|
| 42 | Selective Self-test supported.
|
|---|
| 43 | SMART capabilities: (0x0003) Saves SMART data before entering
|
|---|
| 44 | power-saving mode.
|
|---|
| 45 | Supports SMART auto save timer.
|
|---|
| 46 | Error logging capability: (0x01) Error logging supported.
|
|---|
| 47 | General Purpose Logging supported.
|
|---|
| 48 | Short self-test routine
|
|---|
| 49 | recommended polling time: ( 2) minutes.
|
|---|
| 50 | Extended self-test routine
|
|---|
| 51 | recommended polling time: ( 95) minutes.
|
|---|
| 52 | Conveyance self-test routine
|
|---|
| 53 | recommended polling time: ( 5) minutes.
|
|---|
| 54 | SCT capabilities: (0x30b5) SCT Status supported.
|
|---|
| 55 | SCT Feature Control supported.
|
|---|
| 56 | SCT Data Table supported.
|
|---|
| 57 |
|
|---|
| 58 | SMART Attributes Data Structure revision number: 16
|
|---|
| 59 | Vendor Specific SMART Attributes with Thresholds:
|
|---|
| 60 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
|---|
| 61 | 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
|---|
| 62 | 3 Spin_Up_Time POS--K 139 137 021 - 4033
|
|---|
| 63 | 4 Start_Stop_Count -O--CK 100 100 000 - 59
|
|---|
| 64 | 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
|---|
| 65 | 7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
|---|
| 66 | 9 Power_On_Hours -O--CK 098 098 000 - 1713
|
|---|
| 67 | 10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
|---|
| 68 | 11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
|---|
| 69 | 12 Power_Cycle_Count -O--CK 100 100 000 - 59
|
|---|
| 70 | 192 Power-Off_Retract_Count -O--CK 200 200 000 - 99
|
|---|
| 71 | 193 Load_Cycle_Count -O--CK 198 198 000 - 7701
|
|---|
| 72 | 194 Temperature_Celsius -O---K 115 107 000 - 28
|
|---|
| 73 | 196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
|---|
| 74 | 197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
|---|
| 75 | 198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
|---|
| 76 | 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
|---|
| 77 | 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
|---|
| 78 | ||||||_ K auto-keep
|
|---|
| 79 | |||||__ C event count
|
|---|
| 80 | ||||___ R error rate
|
|---|
| 81 | |||____ S speed/performance
|
|---|
| 82 | ||_____ O updated online
|
|---|
| 83 | |______ P prefailure warning
|
|---|
| 84 |
|
|---|
| 85 | General Purpose Log Directory Version 1
|
|---|
| 86 | SMART Log Directory Version 1 [multi-sector log support]
|
|---|
| 87 | Address Access R/W Size Description
|
|---|
| 88 | 0x00 GPL,SL R/O 1 Log Directory
|
|---|
| 89 | 0x01 SL R/O 1 Summary SMART error log
|
|---|
| 90 | 0x02 SL R/O 5 Comprehensive SMART error log
|
|---|
| 91 | 0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
|---|
| 92 | 0x06 SL R/O 1 SMART self-test log
|
|---|
| 93 | 0x07 GPL R/O 1 Extended self-test log
|
|---|
| 94 | 0x09 SL R/W 1 Selective self-test log
|
|---|
| 95 | 0x10 GPL R/O 1 SATA NCQ Queued Error log
|
|---|
| 96 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
|---|
| 97 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
|---|
| 98 | 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
|---|
| 99 | 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
|---|
| 100 | 0xbd GPL,SL VS 1 Device vendor specific log
|
|---|
| 101 | 0xc0 GPL,SL VS 1 Device vendor specific log
|
|---|
| 102 | 0xc1 GPL VS 93 Device vendor specific log
|
|---|
| 103 | 0xe0 GPL,SL R/W 1 SCT Command/Status
|
|---|
| 104 | 0xe1 GPL,SL R/W 1 SCT Data Transfer
|
|---|
| 105 |
|
|---|
| 106 | SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
|---|
| 107 | No Errors Logged
|
|---|
| 108 |
|
|---|
| 109 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
|---|
| 110 | No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|---|
| 111 |
|
|---|
| 112 | SMART Selective self-test log data structure revision number 1
|
|---|
| 113 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|---|
| 114 | 1 0 0 Not_testing
|
|---|
| 115 | 2 0 0 Not_testing
|
|---|
| 116 | 3 0 0 Not_testing
|
|---|
| 117 | 4 0 0 Not_testing
|
|---|
| 118 | 5 0 0 Not_testing
|
|---|
| 119 | Selective self-test flags (0x0):
|
|---|
| 120 | After scanning selected spans, do NOT read-scan remainder of disk.
|
|---|
| 121 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|---|
| 122 |
|
|---|
| 123 | SCT Status Version: 3
|
|---|
| 124 | SCT Version (vendor specific): 258 (0x0102)
|
|---|
| 125 | SCT Support Level: 1
|
|---|
| 126 | Device State: DST executing in background (3)
|
|---|
| 127 | Current Temperature: 27 Celsius
|
|---|
| 128 | Power Cycle Min/Max Temperature: 18/28 Celsius
|
|---|
| 129 | Lifetime Min/Max Temperature: 18/36 Celsius
|
|---|
| 130 | Under/Over Temperature Limit Count: 0/0
|
|---|
| 131 | Vendor specific:
|
|---|
| 132 | 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|---|
| 133 | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
|---|
| 134 |
|
|---|
| 135 | SCT Temperature History Version: 2
|
|---|
| 136 | Temperature Sampling Period: 1 minute
|
|---|
| 137 | Temperature Logging Interval: 1 minute
|
|---|
| 138 | Min/Max recommended Temperature: 0/60 Celsius
|
|---|
| 139 | Min/Max Temperature Limit: -41/85 Celsius
|
|---|
| 140 | Temperature History Size (Index): 478 (263)
|
|---|
| 141 |
|
|---|
| 142 | Index Estimated Time Temperature Celsius
|
|---|
| 143 | 264 2018-06-11 12:21 27 ********
|
|---|
| 144 | ... ..( 5 skipped). .. ********
|
|---|
| 145 | 270 2018-06-11 12:27 27 ********
|
|---|
| 146 | 271 2018-06-11 12:28 28 *********
|
|---|
| 147 | 272 2018-06-11 12:29 27 ********
|
|---|
| 148 | 273 2018-06-11 12:30 28 *********
|
|---|
| 149 | ... ..( 20 skipped). .. *********
|
|---|
| 150 | 294 2018-06-11 12:51 28 *********
|
|---|
| 151 | 295 2018-06-11 12:52 27 ********
|
|---|
| 152 | ... ..( 4 skipped). .. ********
|
|---|
| 153 | 300 2018-06-11 12:57 27 ********
|
|---|
| 154 | 301 2018-06-11 12:58 28 *********
|
|---|
| 155 | 302 2018-06-11 12:59 27 ********
|
|---|
| 156 | ... ..( 7 skipped). .. ********
|
|---|
| 157 | 310 2018-06-11 13:07 27 ********
|
|---|
| 158 | 311 2018-06-11 13:08 28 *********
|
|---|
| 159 | 312 2018-06-11 13:09 27 ********
|
|---|
| 160 | 313 2018-06-11 13:10 27 ********
|
|---|
| 161 | 314 2018-06-11 13:11 29 **********
|
|---|
| 162 | ... ..( 31 skipped). .. **********
|
|---|
| 163 | 346 2018-06-11 13:43 29 **********
|
|---|
| 164 | 347 2018-06-11 13:44 30 ***********
|
|---|
| 165 | 348 2018-06-11 13:45 30 ***********
|
|---|
| 166 | 349 2018-06-11 13:46 30 ***********
|
|---|
| 167 | 350 2018-06-11 13:47 29 **********
|
|---|
| 168 | ... ..( 5 skipped). .. **********
|
|---|
| 169 | 356 2018-06-11 13:53 29 **********
|
|---|
| 170 | 357 2018-06-11 13:54 30 ***********
|
|---|
| 171 | ... ..(257 skipped). .. ***********
|
|---|
| 172 | 137 2018-06-11 18:12 30 ***********
|
|---|
| 173 | 138 2018-06-11 18:13 31 ************
|
|---|
| 174 | 139 2018-06-11 18:14 30 ***********
|
|---|
| 175 | ... ..( 7 skipped). .. ***********
|
|---|
| 176 | 147 2018-06-11 18:22 30 ***********
|
|---|
| 177 | 148 2018-06-11 18:23 31 ************
|
|---|
| 178 | 149 2018-06-11 18:24 30 ***********
|
|---|
| 179 | ... ..( 7 skipped). .. ***********
|
|---|
| 180 | 157 2018-06-11 18:32 30 ***********
|
|---|
| 181 | 158 2018-06-11 18:33 31 ************
|
|---|
| 182 | 159 2018-06-11 18:34 30 ***********
|
|---|
| 183 | ... ..( 7 skipped). .. ***********
|
|---|
| 184 | 167 2018-06-11 18:42 30 ***********
|
|---|
| 185 | 168 2018-06-11 18:43 31 ************
|
|---|
| 186 | 169 2018-06-11 18:44 30 ***********
|
|---|
| 187 | ... ..( 7 skipped). .. ***********
|
|---|
| 188 | 177 2018-06-11 18:52 30 ***********
|
|---|
| 189 | 178 2018-06-11 18:53 ? -
|
|---|
| 190 | 179 2018-06-11 18:54 31 ************
|
|---|
| 191 | 180 2018-06-11 18:55 ? -
|
|---|
| 192 | 181 2018-06-11 18:56 31 ************
|
|---|
| 193 | 182 2018-06-11 18:57 ? -
|
|---|
| 194 | 183 2018-06-11 18:58 27 ********
|
|---|
| 195 | 184 2018-06-11 18:59 27 ********
|
|---|
| 196 | 185 2018-06-11 19:00 28 *********
|
|---|
| 197 | ... ..( 2 skipped). .. *********
|
|---|
| 198 | 188 2018-06-11 19:03 28 *********
|
|---|
| 199 | 189 2018-06-11 19:04 29 **********
|
|---|
| 200 | 190 2018-06-11 19:05 29 **********
|
|---|
| 201 | 191 2018-06-11 19:06 30 ***********
|
|---|
| 202 | ... ..( 2 skipped). .. ***********
|
|---|
| 203 | 194 2018-06-11 19:09 30 ***********
|
|---|
| 204 | 195 2018-06-11 19:10 ? -
|
|---|
| 205 | 196 2018-06-11 19:11 22 ***
|
|---|
| 206 | 197 2018-06-11 19:12 ? -
|
|---|
| 207 | 198 2018-06-11 19:13 25 ******
|
|---|
| 208 | 199 2018-06-11 19:14 26 *******
|
|---|
| 209 | ... ..( 3 skipped). .. *******
|
|---|
| 210 | 203 2018-06-11 19:18 26 *******
|
|---|
| 211 | 204 2018-06-11 19:19 27 ********
|
|---|
| 212 | 205 2018-06-11 19:20 28 *********
|
|---|
| 213 | ... ..( 2 skipped). .. *********
|
|---|
| 214 | 208 2018-06-11 19:23 28 *********
|
|---|
| 215 | 209 2018-06-11 19:24 ? -
|
|---|
| 216 | 210 2018-06-11 19:25 18 -
|
|---|
| 217 | 211 2018-06-11 19:26 18 -
|
|---|
| 218 | 212 2018-06-11 19:27 20 *
|
|---|
| 219 | 213 2018-06-11 19:28 20 *
|
|---|
| 220 | 214 2018-06-11 19:29 21 **
|
|---|
| 221 | 215 2018-06-11 19:30 21 **
|
|---|
| 222 | 216 2018-06-11 19:31 23 ****
|
|---|
| 223 | 217 2018-06-11 19:32 24 *****
|
|---|
| 224 | ... ..( 2 skipped). .. *****
|
|---|
| 225 | 220 2018-06-11 19:35 24 *****
|
|---|
| 226 | 221 2018-06-11 19:36 25 ******
|
|---|
| 227 | ... ..( 2 skipped). .. ******
|
|---|
| 228 | 224 2018-06-11 19:39 25 ******
|
|---|
| 229 | 225 2018-06-11 19:40 26 *******
|
|---|
| 230 | 226 2018-06-11 19:41 26 *******
|
|---|
| 231 | 227 2018-06-11 19:42 26 *******
|
|---|
| 232 | 228 2018-06-11 19:43 27 ********
|
|---|
| 233 | ... ..( 5 skipped). .. ********
|
|---|
| 234 | 234 2018-06-11 19:49 27 ********
|
|---|
| 235 | 235 2018-06-11 19:50 28 *********
|
|---|
| 236 | 236 2018-06-11 19:51 27 ********
|
|---|
| 237 | ... ..( 26 skipped). .. ********
|
|---|
| 238 | 263 2018-06-11 20:18 27 ********
|
|---|
| 239 |
|
|---|
| 240 | SCT Error Recovery Control command not supported
|
|---|
| 241 |
|
|---|
| 242 | Device Statistics (GP/SMART Log 0x04) not supported
|
|---|
| 243 |
|
|---|
| 244 | SATA Phy Event Counters (GP Log 0x11)
|
|---|
| 245 | ID Size Value Description
|
|---|
| 246 | 0x0001 2 0 Command failed due to ICRC error
|
|---|
| 247 | 0x0002 2 0 R_ERR response for data FIS
|
|---|
| 248 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
|---|
| 249 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
|---|
| 250 | 0x0005 2 0 R_ERR response for non-data FIS
|
|---|
| 251 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
|---|
| 252 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
|---|
| 253 | 0x0008 2 0 Device-to-host non-data FIS retries
|
|---|
| 254 | 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
|---|
| 255 | 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
|---|
| 256 | 0x000b 2 0 CRC errors within host-to-device FIS
|
|---|
| 257 | 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
|---|
| 258 | 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
|---|
| 259 | 0x8000 4 6205 Vendor specific
|
|---|
| 260 |
|
|---|