Ticket #1050: smartctl-Samsung-Portable-SSD-T5.txt

File smartctl-Samsung-Portable-SSD-T5.txt, 4.1 KB (added by Gabriele Pohl, 6 years ago)

smartctl report

Line 
1# smartctl -d sat -a /dev/sda
2smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.13.0-37-generic] (local build)
3Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
4
5=== START OF INFORMATION SECTION ===
6Device Model: Samsung Portable SSD T5
7Serial Number: [snipped]
8LU WWN Device Id: [snipped]
9Firmware Version: [snipped]
10User Capacity: 250.059.350.016 bytes [250 GB]
11Sector Size: 512 bytes logical/physical
12Rotation Rate: Solid State Device
13Form Factor: mSATA
14Device is: Not in smartctl database [for details use: -P showall]
15ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
16SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
17Local Time is: Sun Mar 18 17:22:31 2018 CET
18SMART support is: Available - device has SMART capability.
19SMART support is: Enabled
20
21=== START OF READ SMART DATA SECTION ===
22SMART overall-health self-assessment test result: PASSED
23
24General SMART Values:
25Offline data collection status: (0x00) Offline data collection activity
26 was never started.
27 Auto Offline Data Collection: Disabled.
28Self-test execution status: ( 0) The previous self-test routine completed
29 without error or no self-test has ever
30 been run.
31Total time to complete Offline
32data collection: ( 0) seconds.
33Offline data collection
34capabilities: (0x53) SMART execute Offline immediate.
35 Auto Offline data collection on/off support.
36 Suspend Offline collection upon new
37 command.
38 No Offline surface scan supported.
39 Self-test supported.
40 No Conveyance Self-test supported.
41 Selective Self-test supported.
42SMART capabilities: (0x0003) Saves SMART data before entering
43 power-saving mode.
44 Supports SMART auto save timer.
45Error logging capability: (0x01) Error logging supported.
46 General Purpose Logging supported.
47Short self-test routine
48recommended polling time: ( 2) minutes.
49Extended self-test routine
50recommended polling time: ( 133) minutes.
51
52SMART Attributes Data Structure revision number: 1
53Vendor Specific SMART Attributes with Thresholds:
54ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
55 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
56 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 2333
57 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 12
58177 Wear_Leveling_Count 0x0013 098 098 000 Pre-fail Always - 31
59179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
60181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
61182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
62183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
63187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
64190 Airflow_Temperature_Cel 0x0032 066 042 000 Old_age Always - 34
65195 Hardware_ECC_Recovered 0x001a 200 200 000 Old_age Always - 0
66199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
67235 Unknown_Attribute 0x0012 099 099 000 Old_age Always - 11
68241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 3779771706
69
70SMART Error Log Version: 1
71No Errors Logged
72
73SMART Self-test log structure revision number 1
74No self-tests have been logged. [To run self-tests, use: smartctl -t]
75
76SMART Selective self-test log data structure revision number 1
77 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
78 1 0 0 Not_testing
79 2 0 0 Not_testing
80 3 0 0 Not_testing
81 4 0 0 Not_testing
82 5 0 0 Not_testing
83 255 0 65535 Read_scanning was never started
84Selective self-test flags (0x0):
85 After scanning selected spans, do NOT read-scan remainder of disk.
86If Selective self-test is pending on power-up, resume after 0 minute delay.