Ticket #1049: smartctl-Freecom-0xfc17-ST1500LM012-1R817G.txt

File smartctl-Freecom-0xfc17-ST1500LM012-1R817G.txt, 5.1 KB (added by Gabriele Pohl, 6 years ago)

smartctl report

Line 
1smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-119-generic] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: ST1500LM012-1R817G
6Serial Number: WDZ3AGR7
7LU WWN Device Id: 5 000c50 0a8c679df
8Firmware Version: SBK2
9User Capacity: 1 500 301 910 016 bytes [1,50 TB]
10Sector Sizes: 512 bytes logical, 4096 bytes physical
11Rotation Rate: 5400 rpm
12Form Factor: 2.5 inches
13Device is: Not in smartctl database [for details use: -P showall]
14ATA Version is: ACS-3 T13/2161-D revision 3b
15SATA Version is: SATA 3.1, 6.0 Gb/s (current: 1.5 Gb/s)
16Local Time is: Sat Apr 21 06:33:30 2018 CEST
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19
20=== START OF READ SMART DATA SECTION ===
21SMART overall-health self-assessment test result: PASSED
22
23General SMART Values:
24Offline data collection status: (0x00) Offline data collection activity
25 was never started.
26 Auto Offline Data Collection: Disabled.
27Self-test execution status: ( 0) The previous self-test routine completed
28 without error or no self-test has ever
29 been run.
30Total time to complete Offline
31data collection: ( 0) seconds.
32Offline data collection
33capabilities: (0x71) SMART execute Offline immediate.
34 No Auto Offline data collection support.
35 Suspend Offline collection upon new
36 command.
37 No Offline surface scan supported.
38 Self-test supported.
39 Conveyance Self-test supported.
40 Selective Self-test supported.
41SMART capabilities: (0x0003) Saves SMART data before entering
42 power-saving mode.
43 Supports SMART auto save timer.
44Error logging capability: (0x01) Error logging supported.
45 General Purpose Logging supported.
46Short self-test routine
47recommended polling time: ( 1) minutes.
48Extended self-test routine
49recommended polling time: ( 249) minutes.
50Conveyance self-test routine
51recommended polling time: ( 2) minutes.
52SCT capabilities: (0x3035) SCT Status supported.
53 SCT Feature Control supported.
54 SCT Data Table supported.
55
56SMART Attributes Data Structure revision number: 10
57Vendor Specific SMART Attributes with Thresholds:
58ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
59 1 Raw_Read_Error_Rate 0x000f 100 064 006 Pre-fail Always - 323904
60 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
61 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 37
62 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
63 7 Seek_Error_Rate 0x000f 083 060 045 Pre-fail Always - 4500453109
64 9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 5682 (176 189 0)
65 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
66 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 21
67184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
68187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
69188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
70189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
71190 Airflow_Temperature_Cel 0x0022 066 059 040 Old_age Always - 34 (Min/Max 28/36)
72191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 5
73192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
74193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 325698
75194 Temperature_Celsius 0x0022 034 041 000 Old_age Always - 34 (0 19 0 0 0)
76197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
77198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
78199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
79240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 5286 (213 209 0)
80241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2920101564
81242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 9916862
82254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
83
84SMART Error Log Version: 1
85No Errors Logged
86
87SMART Self-test log structure revision number 1
88No self-tests have been logged. [To run self-tests, use: smartctl -t]
89
90SMART Selective self-test log data structure revision number 1
91 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
92 1 0 0 Not_testing
93 2 0 0 Not_testing
94 3 0 0 Not_testing
95 4 0 0 Not_testing
96 5 0 0 Not_testing
97Selective self-test flags (0x0):
98 After scanning selected spans, do NOT read-scan remainder of disk.
99If Selective self-test is pending on power-up, resume after 0 minute delay.
100