Ticket #1003: smartctl-Iomega-MDHD500-U.txt

File smartctl-Iomega-MDHD500-U.txt, 6.9 KB (added by Gabriele Pohl, 6 years ago)

smartctl report

Line 
1smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.67] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Model Family: Hitachi Deskstar 7K500
6Device Model: HDS725050KLAT80
7Firmware Version: K2AOAB0A
8User Capacity: 500.107.862.016 bytes [500 GB]
9Sector Size: 512 bytes logical/physical
10Device is: In smartctl database [for details use: -P show]
11ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
12Local Time is: Sat Dec 9 04:18:05 2017 CET
13SMART support is: Available - device has SMART capability.
14SMART support is: Enabled
15AAM feature is: Disabled
16APM feature is: Disabled
17Rd look-ahead is: Enabled
18Write cache is: Enabled
19ATA Security is: Disabled, NOT FROZEN [SEC1]
20Write SCT (Get) Feature Control Command failed: Read of ATA output registers not implemented [JMicron]
21Wt Cache Reorder: Unknown (SCT Feature Control command failed)
22
23=== START OF READ SMART DATA SECTION ===
24SMART Status not supported: Incomplete response, status byte missing [JMicron]
25SMART overall-health self-assessment test result: PASSED
26Warning: This result is based on an Attribute check.
27
28General SMART Values:
29Offline data collection status: (0x00) Offline data collection activity
30 was never started.
31 Auto Offline Data Collection: Disabled.
32Self-test execution status: ( 0) The previous self-test routine completed
33 without error or no self-test has ever
34 been run.
35Total time to complete Offline
36data collection: (10419) seconds.
37Offline data collection
38capabilities: (0x5b) SMART execute Offline immediate.
39 Auto Offline data collection on/off support.
40 Suspend Offline collection upon new
41 command.
42 Offline surface scan supported.
43 Self-test supported.
44 No Conveyance Self-test supported.
45 Selective Self-test supported.
46SMART capabilities: (0x0003) Saves SMART data before entering
47 power-saving mode.
48 Supports SMART auto save timer.
49Error logging capability: (0x01) Error logging supported.
50 General Purpose Logging supported.
51Short self-test routine
52recommended polling time: ( 1) minutes.
53Extended self-test routine
54recommended polling time: ( 174) minutes.
55SCT capabilities: (0x003f) SCT Status supported.
56 SCT Error Recovery Control supported.
57 SCT Feature Control supported.
58 SCT Data Table supported.
59
60SMART Attributes Data Structure revision number: 16
61Vendor Specific SMART Attributes with Thresholds:
62ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
63 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
64 2 Throughput_Performance P-S--- 100 100 050 - 0
65 3 Spin_Up_Time POS--- 108 108 024 - 641 (Average 645)
66 4 Start_Stop_Count -O--C- 100 100 000 - 584
67 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
68 7 Seek_Error_Rate PO-R-- 100 100 067 - 0
69 8 Seek_Time_Performance P-S--- 100 100 020 - 0
70 9 Power_On_Hours -O--C- 100 100 000 - 4556
71 10 Spin_Retry_Count PO--C- 100 100 060 - 0
72 12 Power_Cycle_Count -O--CK 100 100 000 - 463
73192 Power-Off_Retract_Count -O--CK 100 100 050 - 735
74193 Load_Cycle_Count -O--C- 100 100 050 - 735
75194 Temperature_Celsius -O---- 114 114 000 - 48 (Min/Max 16/58)
76196 Reallocated_Event_Count -O--CK 100 100 000 - 0
77197 Current_Pending_Sector -O---K 100 100 000 - 0
78198 Offline_Uncorrectable ---R-- 100 100 000 - 0
79199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
80 ||||||_ K auto-keep
81 |||||__ C event count
82 ||||___ R error rate
83 |||____ S speed/performance
84 ||_____ O updated online
85 |______ P prefailure warning
86
87ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron]
88Read GP Log Directory failed
89
90SMART Log Directory Version 1 [multi-sector log support]
91Address Access R/W Size Description
920x00 SL R/O 1 Log Directory
930x01 SL R/O 1 Summary SMART error log
940x06 SL R/O 1 SMART self-test log
950x09 SL R/W 1 Selective self-test log
960x80-0x9f SL R/W 16 Host vendor specific log
970xe0 SL R/W 1 SCT Command/Status
980xe1 SL R/W 1 SCT Data Transfer
99
100SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
101
102SMART Error Log Version: 1
103No Errors Logged
104
105SMART Extended Self-test Log (GP Log 0x07) not supported
106
107SMART Self-test log structure revision number 1
108Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
109# 1 Short offline Completed without error 00% 4556 -
110
111Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
112SMART Selective self-test log data structure revision number 1
113 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
114 1 0 0 Not_testing
115 2 0 0 Not_testing
116 3 0 0 Not_testing
117 4 0 0 Not_testing
118 5 0 0 Not_testing
119Selective self-test flags (0x0):
120 After scanning selected spans, do NOT read-scan remainder of disk.
121If Selective self-test is pending on power-up, resume after 0 minute delay.
122
123SCT Status Version: 2
124SCT Version (vendor specific): 256 (0x0100)
125SCT Support Level: 1
126Device State: Active (0)
127Current Temperature: 48 Celsius
128Power Cycle Max Temperature: 49 Celsius
129Lifetime Max Temperature: 58 Celsius
130
131SCT Temperature History Version: 2
132Temperature Sampling Period: 1 minute
133Temperature Logging Interval: 1 minute
134Min/Max recommended Temperature: 5/60 Celsius
135Min/Max Temperature Limit: -40/65 Celsius
136Temperature History Size (Index): 128 (50)
137
138Index Estimated Time Temperature Celsius
139 51 2017-12-09 02:11 48 *****************************
140 ... ..( 31 skipped). .. *****************************
141 83 2017-12-09 02:43 48 *****************************
142 84 2017-12-09 02:44 49 ******************************
143 ... ..( 16 skipped). .. ******************************
144 101 2017-12-09 03:01 49 ******************************
145 102 2017-12-09 03:02 48 *****************************
146 ... ..( 75 skipped). .. *****************************
147 50 2017-12-09 04:18 48 *****************************
148
149Write SCT (Get) Error Recovery Control Command failed: Read of ATA output registers not implemented [JMicron]
150SCT (Get) Error Recovery Control command failed
151
152Device Statistics (GP/SMART Log 0x04) not supported
153
154SATA Phy Event Counters (GP Log 0x11) not supported
155